background image

3

 

Installation 

3.1

 

Set Up 

 

1. Place the CPAP device on the heater platform. Position the 

CPAP device so that the four feet match up with the four 
recessed areas in the platform and the rubber tab at the 
back of the platform slips into the slot in the rear of the 
CPAP unit (beneath the power socket) locking the device 
securely into place. 

 

2. Place the CPAP and heated humidifier base on a flat surface 

and at a lower level than your sleeping position. 

 

3.

 

Connect the power jumper cord to the power socket 
(outlet) on the back of the heater and the AC inlet on the 
back of the CPAP device.   

 

 

4. Connect the AC power cord to the power socket (inlet) on 

the back of the heated humidifier base, and plug it into 
main outlet.   

NOTE: 

The plug is also serves as a disconnect device.

 

 
 

4

 

Operation 

4.1

 

Operating instruction 
Daily Use 

1.

 

Power on the heater by pressing the On/Off switch on the rear 
of the heated humidifier base. The power on indicator will be lit 
(green light) 

 

2.

 

Fill the chamber to the fill line                          with distilled water 
(approx. 450 ml). 

 

3.

 

Press down and slide the chamber into place. Make sure the 
silicon connector on the inlet connector fit securely over the 
CPAP device air outlet. 

       

Note:

  Make sure the water chamber is pushed to the end to 

press against the heater plate switch. At the same time, 
the heater on indicator will be lit to indicate the heater 
plate starts to warm. 

Note:

 The heater will be automatically turned off while the 

water chamber is removed from the heater platform.   

 

 

 

4.

 

Connect the 6’ flexible tubing to the outlet connector on the 
water chamber. 

 

Silicon  
Connector

Heater Plate 
Switch 

6

Содержание ZZZ-Pap

Страница 1: ...rlboro New Jersey 07746 www pmiusa biz 666005 6130 V1 0 Integrated Heated Humidifier Owner s Manual Probasics Zzz PAP with Integrated Heated Humidifier Model No 9S 003 Series Item No 7501 Please read...

Страница 2: ...RRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES IF ANY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULR PURPOSE AND SHALL NOT EXTEND BEYONG THE DURATION...

Страница 3: ...ANTY SHALL BE LIMITED TO SUCH REPAIR AND OR REPLACEMENT FOR WARRANTY SERVICE PLEASE CONTACT THE DEALER FROM WHOM YOU PURCHASED YOU PMI PRODUCT IN THE EVENT YOU DO NOT RECEIVE SATISFACTORY WARRANTY SER...

Страница 4: ...ry therapist or physician z Never operate this product if a it has a damaged cord or plug b it is not working properly c it has been dropped or damaged d it has been dropped into water Return the prod...

Страница 5: ...e power supply 2 Consult your homecare provider for other technical documents 9 NOTE CAUTION AND WARNING STATEMENTS DANGER Danger indicates an immediately hazardous situation which will result in deat...

Страница 6: ...s or doesn t work correctly for any reason contact your homecare provider immediately Never try to open the enclosure of heated humidifier The heated humidifier requires servicing by qualified mainten...

Страница 7: ...ems of the chamber are subject to normal wear and tear and may eventually be replaced Replace the chamber assembly as necessary 7 2 Product description Water Chamber The water chamber contains the wat...

Страница 8: ...main outlet NOTE The plug is also serves as a disconnect device 5 4 Operation 4 1 Operating instruction Daily Use 1 Power on the heater by pressing the On Off switch on the rear of the heated humidif...

Отзывы: