![ProAudio INTERCOM 200 Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/proaudio/intercom-200-series/intercom-200-series_user-manual_1608032002.webp)
LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
» SICUREZZA
INTERCOM 200 series »
IC230M
User Manual
Connectors and controls
The IEC 3 pin mains connector (2) is the mains power input.
The mains POWER switch (3) switches the unit on and off.
The on LED (4) is lighted when the unit is powered on.
The short LED (5), when lighted, indicates a short circuit in cable connected to the output connectors (usually between pins 1 and 2 ).
The rear panel connectors (male 3 pin XLR) LINE A e LINE B (1) are connected to the remote intercom stations.
Each line’s two connectors are wired in parallel.
The two intercom lines are indipendent (split) or joined (common) according to the front panel LINES switch (8).
The front panel connector (male 3 pin XLR) (9) may be used to connect a beltpack station, used as a master (11),
that may be connected to the A or B intercom line using the front panel TALK TO switch (9).
If the lines are interconnected (common), this station will be always connected to both lines, for any setting of the TALK TO switch (9).
CALL A (6) and CALL B (7) LEDs flash to indicate that a station on the corresponding line has sent a call signal.
For connection to the remote stations, it is
possible to use standard microphone cable ( 2
conductors + screen) (12) , but, in case of very
long connections we strongly suggest to use a 3
conductors + screen cable, having at least 0.18
mm2 conductors, using the third conductor to
connect the XLR connector’s body (frame) (13).
Maximum cable length may be more than 500
m, if cables with large conductors and good
screening are used.
ICH01 or ICH02
headset
1
2
3
4 5
6 7
8
9
10
General
Mains supply voltage
230 V a.c. nominal (220/240 V a.c.), ±10 %, 50÷60 Hz
Output voltage
28V d.c.
Maximum output current
1,1 A
Output Voltage Regulation
better than 2% (for ±10% mains voltage variation and 0 to 100% output load variation.
Protection
automatic electronic protection against electrical overloads and overheating, no manual resets
Intercom line impedance
220 Ω for audio signals, 4700 Ω d.c.
Maximum number of remote stations
30 x IC200B (headset stations) or 10 x IC210A (speaker station)
Call indicators
Sensitivity
+ 2 V d.c on audio line
Size and weight
Dimensions
483 x 44 x 190 mm (W x H x D) ( 1 unit, 19” standard rack)
Weight
2800 g (excluding power supply cable)
Technical specifications
• Read all documentation before using your equipment. Retain all documentation for further reference. • Do not use this apparatus near water. • Clean only with a dry cloth. •
Do not block any ventilation openings. • Do not install near any heat sources such as radiators, heat exchangers, stoves, or other apparatus that produce heat.
• Mains voltage must be correct and the same as that printed on the rear of the unit. • Always operate the unit with the AC ground wire connected to the electrical system
ground. • Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
• Unplug this apparatus during lightning storms or when unused for long periods of time. • Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate normally, or has been dropped. • Always replace the internal mains fuse with one of the same type and rating ( 1A, slow
burn type T, 5x20 mm, 250V)
For further information, please contact our Service Center: tel. +39 0771 72190 fax +39 0771 721955 [email protected]
WARNING! Please read the instruction carefully which include important information about the installation and usage.
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
NO USER SERVICEABLE PARTS INSIDE - REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
11
GB
Always replace the inter-
nal mains fuse with one of
the same type and rating
( 1A, slow blow, Type T,
5x20 mm, 250V)
The unit is compatible with other manufacturers systems. Compatibility data sheet may be supplied on request.
Compatibility
FP- 10 /05/09 - Rev001 - 05/09 ©2009 Music & Lights s.r.l. - Italy - www.proaudioline.it
12
2 cond screen wired cable.
( Microphonic standard cable ).
13
3 cond screen wired cable.
( Suggested for very long connections ).
XLR 3P M
XLR 3P F
2 4 1
3
1 4 2
3
(1) GROUND (screen)
(2) SUPPLY
(4) FRAME
(3) AUDIO
2
1
3
1
2
3
(1) GROUND (screen)
(2) SUPPLY
(3) AUDIO
XLR 3P M
XLR 3P F