ProAudio INTERCOM 200 Series Скачать руководство пользователя страница 2

LINK

INPUT

LINK

INPUT

LINK

INPUT

LINK

INPUT

LINK

INPUT

LINK

INPUT

LINK

INPUT

» SICUREZZA

INTERCOM 200 series » 

IC230M

User Manual

Connectors and controls

The IEC 3 pin mains connector  (2) is the mains power input. 

The mains  POWER switch (3) switches the unit on and off. 

The  on LED (4) is lighted when the unit is powered on.

The  short LED (5), when lighted, indicates a short circuit in cable connected to the output connectors (usually between pins 1 and 2 ).

The rear panel connectors (male 3 pin XLR)  LINE A e LINE B (1) are connected to the remote intercom stations.

Each line’s two connectors are wired in parallel.

The two intercom lines are indipendent (split) or joined (common) according to the front panel LINES switch (8).

The front panel connector (male 3 pin XLR)  (9) may be used to connect a beltpack station, used as a master (11),

that may be connected to the A or B intercom line using  the front panel TALK TO switch (9).

If the lines are interconnected (common), this station will be always connected to both lines,  for any setting of the TALK TO switch (9).

CALL A (6) and CALL B (7)  LEDs flash to indicate that a station on the corresponding line has sent a call signal.

For  connection  to  the  remote  stations,  it  is 
possible  to  use  standard  microphone  cable  (  2 
conductors  + screen) (12) , but, in case of very 
long connections we strongly suggest to use a  3 
conductors  + screen cable, having at least  0.18 
mm2  conductors,  using  the  third  conductor  to 
connect the XLR connector’s body (frame) (13).  
Maximum  cable  length  may  be  more  than  500 
m,  if  cables  with  large  conductors  and  good 
screening are used.

ICH01 or ICH02

headset

1

2

3

4 5

6 7

8

9

10

General

Mains supply voltage

230 V a.c. nominal (220/240 V a.c.), ±10 %,  50÷60 Hz

Output voltage

28V d.c.

Maximum output current

1,1 A

Output Voltage Regulation

better than  2% (for ±10% mains voltage variation and  0 to 100% output load variation.

Protection

automatic electronic protection against electrical overloads and overheating, no manual resets

Intercom line impedance

220 Ω for audio signals, 4700 Ω d.c.

Maximum number of remote stations

30 x IC200B (headset stations) or 10 x IC210A (speaker station)

Call indicators

Sensitivity

+ 2 V d.c on audio line

Size and weight

Dimensions

483 x 44 x 190   mm (W x H x D) ( 1 unit,  19”  standard rack)

Weight

2800  g (excluding power supply cable)

Technical specifications 

• Read all documentation before using your equipment. Retain all documentation for further reference. • Do not use this apparatus near water. • Clean only with a dry cloth. • 

Do not block any ventilation openings. • Do not install near any heat sources such as radiators, heat exchangers, stoves, or other apparatus that produce heat.

• Mains voltage must be correct and the same as  that printed on the rear of the unit.   • Always operate the unit with the AC ground wire connected to the electrical system 

ground. • Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

• Unplug this apparatus during lightning storms or when unused for long periods of time. • Refer all servicing to qualified service personnel. Servicing is required when the 

apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has 

been exposed to rain or moisture, does not operate normally, or has been dropped. • Always replace the internal mains fuse with one of the same type and rating ( 1A, slow 

burn type T, 5x20 mm, 250V)

For further information, please contact our Service Center: tel. +39 0771 72190   fax +39 0771 721955 [email protected]

WARNING! Please read the instruction carefully which include important information about the installation and usage.

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE 

NO USER SERVICEABLE PARTS INSIDE - REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. 

11

GB

Always  replace  the  inter-
nal mains fuse with one of 
the  same  type  and  rating 
(  1A,  slow  blow,  Type  T, 
5x20 mm, 250V)

The unit  is compatible with other manufacturers systems. Compatibility data sheet may be supplied on request.

Compatibility

FP- 10 /05/09 - Rev001  - 05/09  ©2009 Music & Lights s.r.l.   -   Italy   -   www.proaudioline.it

12

2 cond screen wired cable.
( Microphonic standard cable ).

13

3 cond screen wired cable.
( Suggested for very long connections ).

XLR 3P M

XLR 3P F

2 4 1

3

1 4 2

3

(1) GROUND (screen)

(2) SUPPLY

(4) FRAME

(3) AUDIO

2

1

3

1

2

3

(1) GROUND (screen)

(2) SUPPLY

(3) AUDIO

XLR 3P M

XLR 3P F

Отзывы: