![ProAir 600 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/proair/600/600_operation-maintenance-and-technical-manual_1607955010.webp)
10
e.
Refit the filter media into the housing exactly as previously fitted.
f.
Replace the HRV unit cover.
g.
Refit the 4 thumb screws.
2.
Changing the Filter Media.
This should be done on an annual basis. A spare set of filters has been provided for
installation at the end of the first year’s operation. For subsequent years order the
replacement media from ProAir Systems (Order Form at the back of this booklet).
a.
Carry out steps 1.a, 1.b & 1.c.
b.
Remove the filter media from the housing & replace with the new media.
c.
Carry out steps 1.e, 1.f & 1.g.
3.
Three year service by ProAir technician
.
This consists of cleaning the heat exchanger, checking the fans for dirt build-up and
clearing of same, check and cleaning of condensate drain, replacing of filters and
overall check of the system operation.
Check the outdoor intake and exhaust points. Remove leaves, dirt, waste paper or
other obstructions that may be blocking the outside vents of your HRV. Check all the
ductwork leading to and from your HRV.
If ductwork is damaged, crushed, kinked etc. contact ProAir to have it repaired
correctly.
A record of all maintenance work done should be kept. A page at the back of this
booklet has been provided for this purpose
.