background image

T855SH

Installation Manual

Pro1 Technologies

Toll Free: 888-776-1427 

Web: www.pro1iaq.com

Hours of Operation: M-F 9AM - 6PM Eastern

 

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes
Yes

Power Type

Battery Power

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Installation Tips

Thermostat Quick Reference

Wiring

Wiring Diagrams

Technician Setup Menu

Setting Humidity

Programming

Features 

Remote Sensor Operation

Specifications

 

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en espanol de este 

manual se puede descargar en 

la pagina web de la compania.

Rev. 2028

     U.S. Registered Trademark. Patents pending

Copyright      2020 All Rights Reserved.

5-8

15-33

1

2-4

Yes
Yes

34-36

Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place.

Installation Tips

2

Note:

 To ensure a solid fit between the 

thermostat and the subbase:

1. 

Mount subbase to a flat wall

2.

 Use screws provided

3.

 Drywall anchors should be flush with the wall

4.

 Wires should be pushed into the wall

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

3

4

Installation Tips

37-44

45

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Subbase Installation

11-14

9-10

Wired Remote Sensing

Yes

P.O. Box 3377
Springfield, MO 65808-3377

Any HVAC system up to 3H/2C with 

standard low voltage controlled humidifier.
Any HVAC system up to 3H/2C with standard 

low voltage controlled de-humidifier.

Yes

Yes

46

47

Содержание T855SH

Страница 1: ...ld be flush with the wall 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature...

Страница 2: ...at or cool is on 2 will appear for the third stage of heat Setpoint Displays the user selectable setpoint temperature Hold is displayed when the thermostat program is permanently overridden System Ope...

Страница 3: ...lay a jumper can be installed between E and W2 Magnet in door Use the bevel on lower ridge Thermostat Quick Reference The low battery icon is displayed when the AA battery power is low Whenever the th...

Страница 4: ...t OFF 5 10 15 30 45 60 or 90 minutes STAGING DELAY OF This feature allows the installer to select the minimum run time for the compressor For example a setting of 4 will force the compressor to run fo...

Страница 5: ...t will turn on at 68 5 F and turn off at approximately 69 F Technician Setup Menu You can configure this thermostat to have 2 or 4 programmable time periods per day Time Periods Only displayed if prog...

Страница 6: ...o select OFF LOW or HIGH OFF configures the display light to come on when the light key or any button is pressed LOW configures the display light to stay on at a low intensity constantly When a button...

Страница 7: ...oor sensor 35 120 HIGH LIMIT Use the or keys to select the Low Limit for the floor sensor 35 120 50 86 86 50 LOW LIMIT OF OFF FREE COOLING The temperature of the floor sensor will be displayed Note On...

Страница 8: ...79 6 80 6 73 8 74 7 75 7 77 2 78 2 80 2 81 2 82 7 75 2 76 3 77 3 78 8 79 8 81 8 82 8 84 3 76 1 77 1 78 1 79 9 80 9 83 4 84 4 86 2 77 78 79 81 82 85 86 88 77 9 79 1 80 3 82 3 83 6 86 6 88 3 91 78 7 80...

Страница 9: ...below HUM Terminal Onlyshowsif humidifyisset to on Usetheleftandrightarrowsto selectoneofthefouroptions ViewtheHUMterminalchart belowforanexplanationof theseoptions ON HUM TERMINAL 1 3 Options for ho...

Страница 10: ...he WAKE OCC1 time period for the weekday setting 4 Time is flashing Use the or key to make your time selection for the weekday WAKE OCC1 time period Note If you want the fan to run continuously during...

Страница 11: ...hat day s WAKE OCC1 time period Note If you want the fan to run continuously during this time period select ON with the FAN key If you want to use IAQ mode during this time period select IAQ with the...

Страница 12: ...splay HOLD and RUN SCHED on the bottom of the screen when you press the or key If you do nothing the temperature will remain at this setpoint temporarily for 4 hours The program setpoint will then rep...