Pro1 Technologies T731W Скачать руководство пользователя страница 1

T731W(O)

Installation Manual

Pro1 Technologies

Toll Free : 888-776-1427 

Web: www.pro1iaq.com

Hours of Operation: M-F 9AM - 6PM Eastern

 

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Electric Aux.)

Multi-Stage Systems
Heat Only Systems - Floor or Wall Furnace
Cool Only Systems

Millivolt

Yes
Yes
Yes
Yes

No
No

Yes
Yes
Yes

Power Type

Battery Power

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Installation Tips

Thermostat Quick Reference 

Wiring

Technician Setup

Establishing Communication

Network Specifications

Specifications

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en español de este 

manual se puede descargar en 

la pagina web de la compañia.

Rev. 1950

Mount Thermostat

Align the 4 tabs on the subbase 

with corresponding slots on the 

back of the thermostat, then push 

gently until the thermostat snaps 

in place.

Battery Installation

Battery installation is 

optional if thermostat is 

hardwired (R and C terminal 

connected to 24V power).

Important:

High quality alkaline batteries are recommended. 

Rechargeable batteries or low quality batteries 

do not guarantee a 1-year life span.

Insert 2 AA 

Alkaline batteries 

(included). High 

quality alkaline 

batteries are 

recommended.

Installation Tips

2

4-5 

6-11

12-16

1

2-3 

Installation Tips

Thermostat Quick Reference

Getting to know your thermostat

3

4

Subbase Installation

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind 

   the thermostat

•  In areas that do not require 

   conditioning

•  Where there are dead spots 

   or drafts 

   (in corners or behind doors)

•  Where there might be 

   concealed chimneys or

   pipes

Wall Locations

Vertical Mount

Horizontal Mount

For vertical mount put one screw on the top 
and one screw on the bottom.
For horizontal mount put one screw on the 
left and one screw on the right.

All of our products are mercury free. 

However, if the product you are 

replacing contains mercury, dispose of 

it properly.  Your local waste 

management authority can give you 

instructions on recycling and proper 

disposal.

Pick an installation location that is easy for 

the user to access.  The temperature of the 

location should be representative of the 

building.

Installation Tip

Mercury Notice

Do not install 

thermostat in locations:

Failure to disconnect the power before 

beginning to install this product can 

cause electrical shock or equipment 

damage.

Installation Tip: 

Electrical Hazard

      U.S. Registered Trademark. Patents pending

Copyright      2019 All Rights Reserved.

Heat Pump (With Gas Aux.)

Emergency Heat
Conventional Single Stage Furnace
Geothermal

High and Low Fan Speed

No
No

Yes
Yes

19

Located on the back of thermostat.

P.O. Box 3377
Springfield, MO 65808-3377

Glow in the Dark Light Button
Setpoint Buttons

LCD

System Button

Fan Button

R

17-18

20