Thermostat Quick Reference

The low battery indicator is displayed when the AA battery 

power is low. If the user fails to replace the battery within 21 

days, the screen will only show the low battery indicator but 

maintain all functionality.  If the user fails to replace the batteries 

after an additional 21 days (days 22-42 since first “low battery” 

display) the setpoints will change to 55˚F (Heating) and 85˚F 

(Cooling). If the user adjusts the setpoint away from either of 

these, it will hold for 4 hours then return to either 55˚F or 85˚F.  

After day 63 the batteries must be replaced immediately to 

avoid freezing or overheating because the thermostat will shut 

the unit off until the batteries are changed.

Important:

Battery Installation

Thermostat Quick Reference

Insert 2 AA Alkaline batteries (included). High 

quality Alkaline batteries are recommneded.

Battery installation is 

optional if thermostat is 

hardwired (R and C 

terminal connected to 

24V power).