INSTALLATION MANUAL

A trained, experienced technician 
must install this product.

Carefully read these instructions. You 
could damage this product or cause a 
hazardous condition if you fail to follow 
these instructions.

Need Help?

 

For assistance with this product please 

visit http://www.pro1iaq.com or call Pro1 

Customer Care toll-free at 888-Pro1iaq 

(776-1427) during normal business hours 

(Mon-Fri 9 AM - 6 PM Eastern)

Table of Contents

Thermostat Applications Guide

Page

Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with Battery Backup
 

Power Type

1

n

o

it

p

ir

c

s

e

D

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Multi-stage Systems
Heat Only Systems
Heat Only Systems
Cool Only Systems
Millivolt 

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Rev. 0950

Una versión española de este 
manual puede ser descargada 
en www.pro1iaq.com

® U.S. Registered Trademark. Patents pending.
Copyright © 2010 Pro1 IAQ, Inc. All rights reserved.

Installation Tips
Thermostat Quick Reference
Subbase Installation
Wiring
Technician Setup Menu 
Mounting and Battery Installation
Programming The Thermostat
Specifications

2
3
4
5

6-8

9

10-12

13

This manual covers TopTech models:

TT-S-855 and T855

Содержание Toptech TT-S-855

Страница 1: ...mmon Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Multi stage Systems Heat Only Systems Heat Only Systems Cool Only Systems Millivolt Yes Yes Yes Yes Yes Yes Yes Yes Yes Rev 0950 Una versión española de este manual puede ser descargada en www pro1iaq com U S Registered Trademark ...

Страница 2: ... are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Where appliances could radiate heat Pick an installation location that is easy for the user to access The temperature of the location should be representative of the building Wal...

Страница 3: ...isplayed when thermostat program is permanently overridden 1 will appear in the display when second stage of heat or cool is on 2 will appear for third stage of heat System operation indicators The COOL HEAT or FAN icon will display when the COOL HEAT or FAN is on NOTE The compressor delay feature is active if these icons are flashing The compressor will not turn on until the 5 minute delay has el...

Страница 4: ...oducts are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and proper disposal Horizontal mount Horizontal mount Vertical mount Vertical mount For vertical mount put one screw top and one screw bottom For horizontal mount put one screw left and one screw right C O B W E W2 R G...

Страница 5: ...ergized in cooling Fan relay Emergency heat relay First stage of heat cool Second stage of cool second stage of heat Auxiliary heat relay third stage of heat This thermostat is shipped from the factory to operate a conventional heating and cooling system This thermostat will also operate a heat pump system See the heat pump configuration step on page 8 of this manual to configure the thermostat fo...

Страница 6: ...s and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable from 0 4 F to 2 F For example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint Pick PA or FU P...

Страница 7: ... or 24 Hour Clock Use the or key to turn on or off ON This feature turns your system on before the WAKE programming time to ensure the enviroment is at the WAKE setpoint when the WAKE time period begins This recovery changes over time based on the previous days experience Morning Recovery Use the or key to select 7d for 7 day 5d for 5 1 1 or 0d for nonprogammable 5d You can configure this thermost...

Страница 8: ... one character to another See note below on operation If selected on you will see the input screen after pressing next step Note If Contractor Call Number is selected ON your phone number will show in the display if there has been a continuous call for heating or cooling for 24 hours or if the light button is held down for 3 seconds To remove the phone number from the display hold the light button...

Страница 9: ...LLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert 2 AA Alkaline batteries included ...

Страница 10: ...ing Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT STEP Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6 7 8 All programmable Pro1 thermostats are shipped with an en...

Страница 11: ...time period Note If you want the fan to run continuously during this time period select ON with the FAN key Press NEXT STEP The setpoint temperature is flashing Use the or key to make your setpoint selection for the weekday WAKE period Press NEXT STEP Repeat steps 4 through 7 for weekday LEAVE time period for weekday RETURN time period and for weekday SLEEP time period Repeat steps 4 through 7 for...

Страница 12: ...STEP Repeat steps 4 thru 7 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period PROGRAMMING THE THERMOSTAT 12 1 2 3 4 5 6 7 8 Monday Repeat steps 4 thru 7 for the remaining days of the week Tuesday Wednesday Thursday Friday Saturday Sunday A Note About Auto Changeover Auto changeover will switch between heating and cooling as needed It is very important to ma...

Страница 13: ...s adjustable from 0 4ºF to 2 0ºF Cooling is adjustable from 0 4ºF to 2 0ºF 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline Energizer batteries 32ºF to 105ºF 0º to 41ºC 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D 13 SPECIFICATIONS CONTACT INFORMATION Specifications Pro1 IAQ Inc 1111 S Glenstone Suite 2 100 Springfield MO 65804 Toll free 1 888 Pro1iaq...

Отзывы: