background image

 

 
 
 

XK3190-DS3 

 

Weighing Display Controller

control 

system weighing indicator

 

 
 
 

Operation Command 

 
 
 

 
 

V 1.01

Содержание XK3190-DS3

Страница 1: ...XK3190 DS3 Weighing Display Controller control system weighing indicator Operation Command V 1 01...

Страница 2: ...etting II Manual Zero Setting Semi auto Zero Setting III Tare Deduction Function IV Set Date and Time V Use of Battery VI Internal Code Display VII Save Data Record VIII Operation of Printing IX Repor...

Страница 3: ...inute second leap year month automatically without the influence from power break down 6 Scoreboard display interface Transmission mode Serial output 20mA electric current loop signal constant current...

Страница 4: ...gs of all pins are marked in Figure 2 3 Figure 2 3 Digital load cell interface Shield T R T R V V Battery Capacit Internal Code Auto Gross Weight Net Weight Stable Tare Null Position Address Calibrati...

Страница 5: ...ur indicator Please choose printers as remmended The printer must be equipped with reliable ground Otherwise this may disturb regular performance of the indicator or even damage the indicator and prin...

Страница 6: ...icator sends out a group of data every 100ms with 3 frames of data contained See the meaning in Figure 2 6 First frame data the mark bit is 0 Signal ground Connect the scoreboard Scoreboard RS233 outp...

Страница 7: ...se with computer 1 Communication interface is equipped with 15 core RS233 connector assembly shared with scoreboard See definition of pins 6 7 and 8 RS232 or 1 2 3 4 and 8 RS422 RS485 in Figure 2 5 2...

Страница 8: ...ommand B Gross weight form a Symbol or b Gross weight value 6 bits From higher to lower g Each frame is composed of 14 groups of data h Decimal point from right to left 0 4 Command C Tare form a Symbo...

Страница 9: ...rates respectively 600 1200 2400 4800 and 9600 baud rates E g 1 5 Press 0 Press Input t F t F 0 Way of serial communication 0 Continuous send mode no reception 1 Appointed answering mode 2 Old D2 cont...

Страница 10: ...o from its memory for use Under weighing displaying state continuous tare operation may be conducted When tare weight is 0 the tare light is off when the indicator meets the requirement of zero settin...

Страница 11: ...s an any 5 bit number other than 00000 the highest bit of parameter Y in the printing parameters is set as 0 and the tare light of indicator is not on two times saving may constitute a complete record...

Страница 12: ...ress Input HL HL 50 Print only when 00 Back to zero 25 Back to 25 F S 50 Back to 50 F S 75 Back to 75 F S 99 Even it s F S for example 50 5 Press 3 Press Input Arr Arr 3 Select print form Arr 0 record...

Страница 13: ...rst and then heavy one or heavy vehicle at first and then empty one as the record is still not complete during the first time of saving LoAd will be displayed on the indicator for about 1 5 seconds fo...

Страница 14: ...heck Press Check Press Check no 0002 t o hn A t n Second time Time Hour Minute Vehicle No Article No Record of the second time Gross Weight Tare Net Weight Press Check End End Return to weighing and d...

Страница 15: ...the article number for record checking e g 23 Then all weighing record of article with serial number 23 will be displayed 3 Press Check Press Check Press Check Press Check Press Check Press Check no 0...

Страница 16: ...de Clear a random weighing record in the instrument 2 Using any record clearing mode will be displayed on the indicator for operator s confirmation When Sure a non zero number press Input for confirma...

Страница 17: ...e after at null position before tare for 30 seconds LED display is off and state indicating sign maintain At this moment it will be back to normal display state by pressing any key or getting out of t...

Страница 18: ...load cell please cut off the power supply of indicator at first Before plugging or unplugging connecting wire of printer please cut off the power supply of printer and indicator at first Before plugg...

Страница 19: ...er one 2 Erd means The digital load cell with address has communication failures 1 If this is a scale in use we may judge whether there is a connection failure or the communication interface of load c...

Страница 20: ...ross Weight kg Tare kg Net Weight kg 0002 12 03 24 12345 033 2 000 0 300 1 700 0003 12 03 24 00888 033 2 000 0 300 1 700 0004 12 04 11 00888 022 2 000 0 300 1 700 Accumulated amount Gross weight 8 000...

Страница 21: ...t 18 00kg Appendix 4 Printing examples 1 An example of manual gross weight preset weighing sheet printing Step Condition Operation Displayed content Note 1 Load article on the scale Press Tare setting...

Страница 22: ...ew article no 5 Press Input LoAd Return to weighing state after 1 5 seconds 6 Loading heavy vehicle wait till the stable indicating light is on Press Printing o 00123 Vehicle no input in Step 2 7 Pres...

Страница 23: ...ating light lights up Press Vehicle No o Original vehicle no 7 Input the required article no E g 00123 o 00123 If the original vehicle number matches please press input directly Do not input the new v...