background image

HEAT PRESS USER’S GUIDE

www.ProWorldInc.com

Pro World Inc.

961 Bethel Ave.

Pennsauken, NJ 08110

Toll Free 800-678-8289

Outside U.S. 856-406-1020

Fax 856-406-1025

Содержание TransPro Slide MP999

Страница 1: ...HEAT PRESS USER S GUIDE www ProWorldInc com Pro World Inc 961 Bethel Ave Pennsauken NJ 08110 Toll Free 800 678 8289 Outside U S 856 406 1020 Fax 856 406 1025 ...

Страница 2: ...hich are made of cotton flax chemical fiber nylon ceramics and glasses and so on The machine also can conduct some heat treatments such as hair planting print vesicant print and conglutination of cloth lining and cloth under low temperature and low pressure such as the conglutination of children clothes caps and shoes Also the machines can be used to smooth and sharp in small amount of caps handke...

Страница 3: ...always displayed 2 When modifying the temperature setting the temperature setting flashes together 3 When modifying the time setting the time setting flashes together 4 During heating output Heating is displayed which is not displayed at ordinary times 5 When the alarm is output Alm flashes and is not displayed at ordinary times 6 SET key is a function key 7 and v keys are parameter addition and s...

Страница 4: ...ction Finished one transfer counter display plus 1 Press and hold CLEAR for more than 3 seconds to clear the counter count value 4 Adjust the Working pressure adjuster to set the working pressure 5 Place the cloth on the down board cover the printing paper please note the right surface of the paper when the temperature ready press the handle down 6 When the temperature is reached press your transf...

Страница 5: ...ed for more than 30 minutes 3 For better maintenance of the heat press the maximum temperature used should be 410 degrees F 4 When printing double sided T Shirts insert a teflon sheet in between the shirt to protect the ink 5 Heat platen may pivot slightly back and forth This is due to movement allowance within the assembled clamp and is normal Troubleshooting 3 The heat platen works well but sudd...

Страница 6: ...WIRING SCHEMATIC www proworldinc com Ko Power Switch X1 Terminal FU Fuse 25A SJ Thermostat KM AC Contactor SA Sensitive Switch CH1 CH2 Electrical Heat Tube KJ Timer HA Buzzer ...

Страница 7: ... is solely the responsibility of the customer Prior to 30 days the shipping costs will be refunded if Pro World deems the equipment to be defective as stated Pro World cannot be held responsible for improper handling or any other damage incurred in transit No charge will be made for labor and components for repair of in warranty equipment OUT OF WARRANTY machines will be charged at the repair rate...

Страница 8: ...www ProWorldInc com Pro World Inc 961 Bethel Ave Pennsauken NJ 08110 Toll Free 800 678 8289 Outside U S 856 406 1020 Fax 856 406 1025 ...

Отзывы: