CD -5 1 2
PRO WEL D
9.2 Reverse Polarity (Recommended for brass or galvanized) (see Figure 3)
A. Connect ground cable connector (1A) into camlok (4). The camlok should be connected into the
receptacle marked GUN. Twist until it locks. Attach “C” clamp (2) to the workpiece (5) (CLEANED
AREA).
B. Connect the gun control cable (3A) into the female receptacle (3).
C. Connect the gun weld cable (4A) into the receptacle marked GROUND (1). Twist clockwise until
it locks.
D. Connect AC power cable to AC outlet.
NOTE:
The gun welding and control cables must be laid out in a straight line. Poor weld quality may
result if welding cables are coiled.
Figure 3 Reverse Polarity Hook-Up
4A
4
1A
1
3
3A
2
5