CO GAS EXPOSURE VERSUS TIME
(400 PPM EXPOSURE
)
MINUTES SYMPTOMS
8 NONE
15 NONE
25 SLIGHT
HEADACHE
35 HEADACHE
45
HEADACHE AND NAUSEA
60 DROWSY
75 VOMITING
90 COLLAPSE
110
COMA AND PERMANENT
BRAIN DAMAGE
140 PERMANENT
BRAIN
DAMAGE – DEATH
2. SPECIFICATIONS
CO RESPONSE TIME
70 PPM
150 PPM
400 PPM
60-240 MINUTES
10-50 MINUTES
4-15 MINUTES
POWER SOURCE
9V BATTERY
SENSOR TYPE
ELECTROCHEMICAL
OPERATING TEMPERATURE
40
o
F (4.4
o
C) TO 100
o
F (37.8
o
C)
AUDIBLE ALARM
85 dB AT 10 FEET
VISUAL ALARM
FLASHING RED LED
DETECTION FREQUENCY
SAMPLES FOR CO EVERY MINUTE
LCD DISPLAY: MODELS 7035/7035SL:
1. DIGITAL READ-OUT OF CURRENT
CO DETECTED AND PEAK LEVEL
MEMORY
DISPLAYS CO LEVELS FROM 10 PPM TO 600
PPM.
2. PEAK LEVEL TIME RECORD (THE
TOTAL TIME CO IS DETECTED
WITHIN 10% OF THE PEAK LEVEL)
DISPLAYS TIME FROM 0 TO 999 MINUTES.
3. DISPLAY TOLERANCE @ 50% RH,
72°F±5° (22°C±3°)
± 15% FROM 40-600 PPM
LIFE MONITOR
ACTIVATES SENSOR EXPIRATION SIGNAL
AFTER FIVE YEARS
BATTERY TYPE
LONG-LIFE ULTRALIFE U9VL-J LITHIUM
POWER CELL (SUPPLIED)
400 PPM EXPOSURE
50%
45%
40%
35%
30%
25%
20%
15%
10%
5%
0%
C
O
H
b 1
0
0
%
8 15 25 35 45 60 75 90 110 140
Minutes