Pro-tec 193762 Скачать руководство пользователя страница 18

Revised 07/14/2017 

 

 
 
 

 
 

N

EW 

P

RODUCT 

W

ARRANTY

 

P

RO

-T

EC 

B

UILDINGS

 

LIMITED

 

WARRANTY

 

FOR

 

NEW

 

SIOUX

 

STEEL

 

COMPANY

 

PRODUCTS 

A.  GENERAL PROVISIONS.  “Sioux Steel” means Sioux Steel Company, 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104.  The warranties 
described below are provided by Sioux Steel to the original purchasers of new products purchased from Sioux Steel or from an authorized Sioux Steel Dealer 
(the “Products”).  Under these warranties, Sioux Steel will, at its option, repair or replace at its factory any Product covered under these warranties which is 
found to be defective in material and workmanship during the applicable warranty term or refund the purchase price paid for the defective Product.  Customer 
will be responsible for labor charges for removing the defective Product and reinstalling the repaired or replacement Product, any premium charge for overtime 
labor requested of Sioux Steel and shipping charges to and from Sioux Steel’s factory.  These warranties are not transferrable
B.  WARRANTY PERIOD.  Subject to exclusions and limitations set forth herein, each new Product is warranted for the number of years specified below.  
Each warranty term begins from the date of purchase regardless of delay in receipt of the Product by Customer due to the time required to process, handle, 
ship, assemble, construct and install the Product.  Customer must retain proof of the date of purchase.  Replacement parts for and repairs to the Product will 
be warranted only for the remainder of the original warranty term.  The replacement parts for or repairs to the Product will not extend the warranty term beyond 
the original warranty term.  Products described below include all parts, components and accessories. 

PROTEC BUILDINGS  

Pro-Tec Poultry Buildings 

1 Year 

Safeguard Livestock Shade 

1 Year 

Pro-Tec Single Tube (24’, 30’, and 36’) Buildings 

3 Years 

All Other Powder-Coated Pro-Tec Buildings in Livestock (other than Poultry) and Chemical Storage Applications 

7 Years, Prorated Monthly 

All Other Powder-Coated Pro-Tec Buildings Except those in Livestock and Chemical Storage Applications   

15 Years, Prorated Monthly 

All Other Hot-Dip Galvanized Pro-Tec Buildings   

15 Years, Prorated Monthly 

Fabricated Tarp Materials (covers)       

15 Years, Prorated Monthly 

Fabricated Tarp Materials for End Panels (All Pro-Tec Buildings) ; Rollup Sides; Curtains and Doors; Track Doors; Quarter 
Panels and Half Moon End Panels ( On all Building Models)  

3 Years, Prorated Monthly 

Proration credit will be given toward the purchase price for the replacement of fabric and tarp materials, based on Sioux Steel’s current price list at the time the 
warranty claim is made.   

15 Year Proration Schedule: 

7 Year Proration Schedule: 

Year 1 = 93% 

Year 4 – 73% 

Year 7 – 53% 

Year 10 = 33% 

Year 13 = 13% 

Year 1 = 86% 

Year 4 = 43% 

Year 7 = 0% 

Year 2 = 87% 

Year 5 = 67% 

Year 8 = 47% 

Year 11 = 27% 

Year 14 = 7% 

Year 2 = 72% 

Year 5 = 29% 

 

Year 3 = 80% 

Year 6 = 60% 

Year 9 = 40% 

year 12 = 20% 

Year 15 = 0% 

Year 3 = 58% 

Year 6 = 15% 

 

Exclusions specific to Pro-Tec Buildings:  Damage or loss of any kind from (1) exposure of the fabric cover or end panel material to any heat source for any 
length of time; (2) a failure to properly compact and engineer soils; (3) a failure to properly construct footings and foundations; and (4) exposure to conditions 
in excess of the design wind and snow load specifications. NOTICE: Caustic and corrosive environments can result from live animal operations or 
storage of caustic materials. Sioux Steel reserves the right to exclude from warranty under D(4) if conditions are deemed by it as extreme.
 
C.  ITEMS COVERED SEPARATELY.  The Sioux Steel warranties do not cover any parts, components or materials that are part of the Product, or used in 
conjunction with the Product, that are not manufactured by Sioux Steel.  Such parts, components and materials will be subject to the warranties provided by 
the manufacturer, if any.   
D.  WHAT IS NOT WARRANTED.  Sioux Steel does not warrant and is not responsible for the following:  (1) used products; (2) modification or alteration of 
the Products; (3) Products that have not been properly installed or not installed in accordance with the instruction manual, improper assembly, or improper 
construction by any persons other than Sioux Steel employees; (4) depreciation, damage or loss caused by the use of parts, components or accessories not 
provided by Sioux Steel, unauthorized repairs, normal wear, lack of necessary and proper maintenance, a failure to follow operating 
instructions/recommendations, misuse, lack of proper protection during storage, vandalism or theft, exposure to the elements or corrosive materials, accidents 
or acts of nature including lightning, flooding, hail, straight winds and tornadoes; and (5) cosmetic damage or damage that does not hinder the functionality of 
the Products. 
E.  LIMITATIONS OF WARRANTIES AND CUSTOMER’S REMEDIES
.  To the extent permitted by law, neither Sioux Steel, the Dealer nor any person or 
company affiliated with either of them makes any warranties, representations, conditions or promises express or implied as to the quality, performance or 
freedom from defects of the Products covered by these warranties other than those set forth herein.  THERE ARE NO IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  NEITHER SIOUX STEEL, THE DEALER, NOR ANY PERSON OR COMPANY 
AFFILIATED WITH EITHER OF THEM WILL BE LIABLE FOR ANY DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCIDENTAL, SPECIAL, 
EXEMPLARY, CONSEQUENTIAL, LOST PROFITS AND REVENUES, LOST USE OF THE PRODUCTS OR ANY OTHER PROPERTY, BODILY INJURY OR 
PROPERTY DAMAGE CLAIMS OF ANY PERSON, LOST COMMODITIES, REMOVAL OR STORAGE COSTS FOR THE PRODUCTS, OTHER EQUIPMENT 
AND COMMODITIES, DAMAGE TO THE ENVIRONMENT ARISING FROM OR IN ANY MANNER RELATED TO ANY RELEASE OF HAZARDOUS 
MATERIALS, AND REMEDIATION EXPENSES THEREFORE, WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR ANY OTHER LEGAL 
BASIS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  IN NO INSTANCE WILL SIOUX STEEL, THE DEALER OR ANY PERSON OR 
COMPANY AFFILIATED WITH EITHER OF THEM BE LIABLE TO CUSTOMER OR ANY PERSON IN AN AMOUNT IN EXCESS OF THE PURCHASE 
PRICE PAID BY CUSTOMER FOR THE PRODUCT. 
F.  NO DEALER WARRANTY
.  THE DEALER HAS NO AUTHORITY TO MAKE ANY WARRANTY, REPRESENTATION, CONDITION OR PROMISE ON 
BEHALF OF SIOUX STEEL, OR TO MODIFY THE TERMS OR LIMITATIONS OF THIS WARRANTY IN ANY WAY. 
G.  GOVERNING LAW/VENUE.  These warranties, and all terms set forth herein, are governed by the laws of the State of South Dakota and, where 
applicable, the laws of the United States of America.  Any and all disputes arising from these warranties, the purchase and use of the Products, bodily injury 
and property damage claims or otherwise must be venued in the South Dakota Circuit Court sitting in Minnehaha County, South Dakota.  Customer agrees to 
such venue and waives any challenge to such court’s jurisdiction based upon lack of personal jurisdiction or inconvenience. 
H.  SECURING WARRANTY SERVICE.  In order to receive warranty services, customer  must give Sioux Steel written notice of a warranty claim within 3 
days of the date of discovery of the defective materials or workmanship, and Customer must complete the following steps: 

(1) 

Obtain from Sioux Steel a Return Goods Authorization Number (“RMA Number”) by calling the Customer Service 
Department at 1-800-557-4689, and providing the following information: 

 

 

 

An explanation as to why the Product is being returned. 

 

 

 

The name of the territory representative, Dealer or Sioux Steel salesperson from whom the Product was 
purchased. 

 

 

 

The Dealer’s identification number. 

 

 

 

The invoice number and date of purchase. 

 

 

 

Customer’s name, phone number, fax number, mailing address and email address. 

 

 

 

The date that the Product will be returned. 

(2) 

Pay the shipping charges to ship the Product to Sioux Steel’s factory, and the return shipping charges. 

(3) 

Ship the Product to Sioux Steel at 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104. 

 

Содержание 193762

Страница 1: ...ING MANUAL IMPORTANT TO THE DEALER OR ERECTOR RETURN THIS MANUAL TO THE OWNER FOR THEIR FUTURE REFERENCE SIOUX STEEL COMPANY P O BOX 1265 SIOUX FALLS SOUTH DAKOTA 57101 1 800 557 4689 MANUAL NO 193762 REV D MRS 8 1 17 ECN 17 141 ...

Страница 2: ...NG FRAME PAGE 7 70 AWNING FRAME PAGE 8 80 AWNING FRAME PAGE 9 90 AWNING FRAME PAGE 10 EAVE INSTALLATION PAGE 11 40 TO 50 RATCHET MOUNT INSTALLATION PAGE 12 60 TO 80 RATCHET MOUNT INSTALLATION PAGE 13 90 RATCHET MOUNT INSTALLATION PAGE 14 COVER SPLICE BRACKET PAGE 15 MAINTENANCE SCHEDULE PAGE 16 17 WARRANTY STATEMENTS PAGE 18 1 ...

Страница 3: ...e erection equipment and proper training in the operation of this equipment are important factors for the safe erection of building Reading understanding and following the instructions in this book are also very important for the safe assembly of this building Sioux Steel Company includes all reasonable means for accident prevention except a safe and careful operator If any decals become damaged d...

Страница 4: ...ocket wrench size 3 8 3 4 Impact Wrench pneumatic or electric Special Tools Movable scaffolding or man lift Material Customer Supplied Duct Tape BOLT INSTALLATION Bolts should be installed to a snug tight condition which is defined as the tightness attained by either a few impacts of an impact wrench or the full effort of a worker with a wrench that brings the connected plates in to a firm contact...

Страница 5: ...GED EAVE 3 193389GRY 10FT 194100GRY 12FT 189988GRY 16FT 2 MOUNT 40 TO 80 189992GRY 90 194105GRY UPPER TUBE 157630 DRILL SCREW 1 4 x 1 1 4 COMPONENTS 189515 1 2 NYLOCK NUT SCALE 1 2 2 MOUNT PLATE USED ON END RAFTERS 90 194104GRY 40 TO 80 189993GRY BRACE ARM 163753 1 2 x 4 BOLT SCALE 1 2 191750 1 2 x 4 1 2 BOLT SCALE 1 2 HORIZONTAL ARM 4 ...

Страница 6: ...ube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 4 drill screws attach Horizontal Arm and Brace Arm to rafter as shown in drawing Step 1 4 Proceed to step 2 STEP 1 40 AWNING FRAM...

Страница 7: ... ARM Step 1 4 Proceed to step 2 in drawing HOLES PRE DRILLED BOLT 1 2 X 3 1 2 DRILL SCREWS 8 1 4 X 1 1 4 Step 1 1 Install Upper Tube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 ...

Страница 8: ...OLT 1 2 X 4 Step 1 1 Install Upper Tube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 4 drill screws attach Horizontal Arm and Brace Arm to rafter as shown 1 2 NUT 1 2 X 3 1 2 BOL...

Страница 9: ...tep 1 1 Install Upper Tube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 4 drill screws attach Horizontal Arm and Brace Arm to rafter as shown DRILL 17 32 1 2 NUT HOLE 1 2 X 4 BOL...

Страница 10: ...tep 1 1 Install Upper Tube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 4 drill screws attach Horizontal Arm and Brace Arm to rafter as shown UPPER TUBE ARM HORIZONTAL BRACE ARM ...

Страница 11: ...ep 1 1 Install Upper Tube as shown in drawing by drilling 17 32 clearance hole into rafter and then securing with 1 2 bolt and nut Step 1 2 Assemble Horizontal Arm and Brace Arm to Upper Tube utilizing existing pre drilled holes and 1 2 bolts and nuts as shown in drawing Step 1 3 Utilizing 1 4 drill screws attach Horizontal Arm and Brace Arm to rafter as shown UPPER TUBE ARM HORIZONTAL BRACE ARM 1...

Страница 12: ...d install Eave 3 as shown in drawing Secure with 1 4 drill screws from underneath at insert connections Step 2 2 Next install Swaged Eave 3 as shown in drawing Secure with 2 1 4 drill screws from underneath at swage and insert connections Step 2 3 Install 3 Tube Caps into end of Eave Tubes as shown in drawing Step 2 4 Duct tape all drill screws and swage connections to prevent abrasion to cover 3 ...

Страница 13: ...ter Rafter detail below Step 3 3 Next secure 2 Mount Plates and 2 Mounts to rafter utilizing 4 1 4 drill screws as shown on drawing Step 3 1 Install 1 2 Mount Plate and 1 2 Mount to each End Rafter by utilizing 189993GRY 2 MOUNT PLATE 189992GRY 2 MOUNT 1 2 x 3 1 2 BOLT 190006 1 2 NYLOCK NUT 189515 1 4 x 1 1 4 DRILL SCREW 157630 4 1 2 NYLOCK CENTER RAFTER BOLT 4 1 2 x 3 1 2 NUT 2 1 4 X 1 1 4 DRILL ...

Страница 14: ...e 2 Mount Plates and 2 Mounts to rafter utilizing 4 1 4 drill screws as shown on drawing 189993GRY 2 MOUNT PLATE 189992GRY 2 MOUNT 1 2 x 4 BOLT 163753 1 2 NYLOCK NUT 189515 1 4 x 1 1 4 DRILL SCREW 157630 STEP 3 60 TO 80 RATCHET MOUNT INSTALLATION 4 1 2 NYLOCK NUT RH END RAFTER 2 1 4 X 1 1 4 DRILL SCREW BOTH SIDES 4 1 2 x 4 BOLT LH END RAFTER NYLOCK NUT 4 1 2 2 1 4 X 1 1 4 DRILL SCREW BOTH SIDES 4 ...

Страница 15: ...ts to rafter utilizing 4 1 4 drill screws Step 3 1 Install 1 2 Mount Plate and 1 2 Mount to each End Rafter by utilizing 194104GRY 2 MOUNT PLATE 194105GRY 2 MOUNT 1 2 x 4 1 2 BOLT 191750 1 2 NYLOCK NUT 189515 1 4 x 1 1 4 DRILL SCREW 157630 DRILL SCREW BOTH SIDES RH END RAFTER NUT NYLOCK 4 1 2 2 1 4 X 1 1 4 4 1 2 x 4 1 2 BOLT 4 1 2 NYLOCK LH END RAFTER BOLT 4 1 2 x 4 1 2 NUT 2 1 4 X 1 1 4 DRILL SCR...

Страница 16: ...gle 193651GRY on upper chord of rafter at splice location as shown below utilizing 4 1 4 x 1 1 4 Drill Screws 157630 Note Mount angle is used for 2 Conestoga ratchets at splice location See Cover manual for additional details DETAIL A SCALE 1 16 193651GRY MOUNT ANGLE 1 3 1 4 APPROX RAFTER AT SPLICE LOCATION 15 ...

Страница 17: ... c Check all base plate anchor studs and nuts to assure they are tight d Check all ratchet mount and winch bolts and nuts to assure they are tight e Check for premature wear of fabric cover especially where tension is applied and where there is direct contact with the buildings steel frame f Check for premature deterioration of the corrosion protection on the building components NOTE Building cove...

Страница 18: ...HAT IS NOT WARRANTED Sioux Steel does not warrant and is not responsible for the following 1 used products 2 modification or alteration of the Products 3 Products that have not been properly installed or not installed in accordance with the instruction manual improper assembly or improper construction by any persons other than Sioux Steel employees 4 depreciation damage or loss caused by the use o...

Отзывы: