background image

6

IP setting

• 

TX and RX units have their own default IP address, TX's IP is 192.168.1.238, and 

RX's IP is 192.168.1.239. Generally, it is not need to change the device IP address, 

as the system can work normally even though multiple TX units and multiple RX 

units connected into the system with their default IP address.

• 

If IP setting is really needed, please follow up the operation as Figure 2 (example of 

TX's IP setting shown, RX 's setting is the same as TX's )

Figure 2

Содержание PSG3456

Страница 1: ...1 HDBiT HDMI EXTENDER MATRIX PSG3456...

Страница 2: ...nplug cables while the devices are powered on WHAT S INCLUDED 1 x HDMI Extender and 1 x Receiver 2 x Power Adapter 230VAC to 5VDC 2A Operation Manual IR remote extender IR remote receiver Remote contr...

Страница 3: ...tor Indicates current transmission channel ID 2 IR receiver window Receiver IR signal from remote control 3 Power indicator LED for power on indication 4 TX connected Indicates current input channel I...

Страница 4: ...as possible to the IR receiving window of the source device Face the receiving head of the IR receiver extension cable toward the user for unobstructed line of sight to the remote control The IR rece...

Страница 5: ...s the TX CONNECTED on the receiver the channel is connected Short press Press to set IGMP group and display the current set value The unit switches automatically to the corresponding IGMP group 5 seco...

Страница 6: ...s not need to change the device IP address as the system can work normally even though multiple TX units and multiple RX units connected into the system with their default IP address If IP setting is...

Страница 7: ...g and setting Device scanning and setting example shown of TX s setting only RX s setting is identical Figure 3 Figure 4 Device Name setting Click on a default device name and enter the desired name i...

Страница 8: ...scroll list Mode setting Click on the Mode button to change the required mode name Click the Update button when complete to store all the settings made Click the Update button when complete to store...

Страница 9: ...9 Selecting the operation Mode Click on the Mode button to change to the required mode and switch to the settings stored previously under that name...

Страница 10: ...ps Input output TMDS signal 0 7 1 2Vp p Input output DDC signal 5Vp p TTL Transmission length CAT5 80m CAT5E 100m CAT6 120m IR remote control Supports IR passback with 20 60KHz frequency Transfer meth...

Страница 11: ...11...

Страница 12: ...ife it must be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling...

Отзывы: