In the setting modes, press 

+

 key or 

MIN/MAX

 key change or scrolls the value. Hold the 

+

key  or

MIN/MAX

 key for 3 second will increase/decrease digits in great steps.

-

Press 

SNOOZE/LIGHT

 key or key idle 10 second, the setting mode will return to Normal Mode

Note: 

Please set the units firstly before change units

’ value. During change of units setting, units’ value 

will  change  according  to  new  units  but  it  might  cause  resolution  loss  due  to  its  internal  calculation 
algorithm. 

5.3 Alarm Modes 

-

While in Normal Mode press the 

ALARM

 key to enter the High Alarm Mode

-

Press the 

ALARM 

key again to enter Low Alarm mode

Remark: after the initial pressing of 

ALARM

 key, the display will be refreshed to show current high,

 

low

alarm value. Normal alarm value will be displayed only for those already activated, all other not

 

activated

values will be displayed 

with “---“or” --“instead.

Press the 

ALARM

 key again to return the Normal Mode

In the High Alarm Mode press the 

SET

 key to select the following alarm modes:

1.

Time alarm (hour/minute)

2.

Indoor humidity high alarm

3.

Indoor temperature high alarm

4.

Outdoor humidity high alarm

5.

Outdoor temperature and dew point high alarm

6.

Pressure high alarm

-

In the Low Alarm Mode press the 

SET

 key to select the following alarm  modes:

1.

Time alarm (hour/minute)

2.

Indoor humidity low alarm

3.

Indoor temperature low alarm

4.

Outdoor humidity low alarm

5.

Outdoor temperature and dew point low alarm

6.

Pressure low alarm

Canceling the Temperature Alarm While Sounding 

a. When a set weather alarm condition has been activated, that particular alarm will sound and flash for 120
second. Press any key to mute the alarm. When weather alarm condition was activated again within 10
minutes, alarm will not sound but will continue to flash until weather conditions have become more steady.
This feature is useful to avoid repeated triggering for the same alarm value.
b. The alarm will reactivate automatically once the value has fallen below the set value, or if a new value is
entered.

The outdoor weather alarms   

When a set outdoor weather alarm has been triggered, it will flash on the LCD display and the general 
outdoor alarm icon and high/low alarm icon will flash accordingly. For example, in outdoor temperature 
display mode, when dew point high alarm is triggered, 

DEW POINT

 icon will flash along with general 

outdoor alarm icon and high alarm icon flashing, telling that the current alarm source is from dew point. 

In the alarm modes, Press + key or MIN/MAX key change or scrolls the alarm value. Hold the + key or 

MIN/MAX key for 3 second to change the number in greater step. Press the ALARM key to choose the 

alarm on or off (if alarm is enabled, the speaker icon on the LCD will be turned on indicating the alarm 

function has been enabled). Press the SET key to confirm the setting and continue pressing the SET key 

to toggle through each alarm mode until it returns to the normal display mode.

Press SNOOZE/LIGHT key or key idle 10 second at any time, the alarm mode will return to Normal Mode

3)

Calendar setting (year /month /date)

4)

Temperature display unit degree Celsius or Fahrenheit

5)

Air pressure display units in hPa or inHg

6)

Relative pressure setting from 919.0hPa – 1080.0hPa (default 1013.5hPa)

7)

Pressure threshold setting (default 2hPa)

8)

Storm threshold setting (default 4hPa)

Содержание PSG04175

Страница 1: ...d should be kept in a safe place for future reference It contains important notes on setup and operation 2 2 2 2 4 5 5 5 5 5 6 7 8 8 3 3 3 4 7 y Do not expose the main unit to rain or moisture y Use o...

Страница 2: ...ll pick up the signal from the transmitter To measure outdoor temperature place the transmitter outdoors It will transmit the temperature from its location Every time the remote sensor is powered up f...

Страница 3: ...educe the range If a north facing wall is not possible choose a shaded area under an eve 1 Use a screw or nail to affix the remote sensor to the wall 2 Hang the remote sensor up using string or a zip...

Страница 4: ...ure display 22 General outdoor alarm icon 23 Weather tendency indicator 24 Barometer air pressure 25 Pressure display unit inHg or hPa 26 Pressure alarm on indicator 4 2 Weather forecasting Sunny Part...

Страница 5: ...uires a higher setting compared to an area where the air pressure is stagnant For example if 4hPa is selected then there must be a fall or rise in air pressure of at least 4hPa before the weather stat...

Страница 6: ...particular alarm will sound and flash for 120 second Press any key to mute the alarm When weather alarm condition was activated again within 10 minutes alarm will not sound but will continue to flash...

Страница 7: ...aximum value will be reset to current reading 1 Indoor humidity maximum 2 Indoor temperature maximum 3 Outdoor humidity maximum 4 Outdoor temperature maximum 5 Outdoor dewpoint maximum 6 Pressure maxi...

Страница 8: ...ield Frequency Temperature range Resolution Measuring range rel humidity Humidity accuracy 100meter max 433MHz 40 to 60 displays OFL if outside range 0 1 20 95 5 within 0 45 48 sec IPX3 48 sec 0 to 60...

Отзывы: