PRO SIGNAL PSG04174 Скачать руководство пользователя страница 15

Temperature Calibration 

Temperature errors can occur when a sensor is placed too close to a 
heat source (such as a building structure, the ground and when placed 
in direct sunlight without proper shielding in hot weather environments). 

To calibrate temperature, we recommend a mercury or red spirit (fluid) 
thermometer. Bi-metal (dial) and other digital thermometers are not a 
good source and have their own margin of error. Using a local weather 
station in your area is also a poor source due to changes in location, 
timing (airport weather stations are only updated once per hour) and 
possible calibration errors (many official weather stations are not 
properly installed and calibrated). 

Place the sensor in a shaded, controlled environment next to the fluid 
thermometer, and allow the sensor to stabilize for 48 hours. Compare 
this temperature to the fluid thermometer and adjust the console to 
match the fluid thermometer. 

Humidity Calibration 

Humidity is a difficult parameter to measure accurately and drifts over 
time. Humidity errors can occur when placed too close to the ground, 
near grass or other sources of humidity. 

The hygrometer sensor utilizes a capacitor, which varies as a function 
of humidity. Due to manufacturing tolerances, the accuracy of the 
sensor is ± 5%. To improve on this accuracy, the indoor and outdoor 
humidity readings can be adjusted or calibrated from the display 
console. 

To calibrate humidity, you will need an accurate source, such as a 
sling psychrometer or Humidipaks One Step Calibration kit. 

Rainfall calibration  

The Rain Collector is calibrated at the factory so the bucket tips (and 
records rainfall) for each 0.01" (or 0.3 mm) of rain. To calibrate rainfall, 
we recommend a tube type rain gauge. Use a rain gauge with an 
aperture of at least 4 inches. Any smaller and the readings obtained 

15

 

Содержание PSG04174

Страница 1: ...batteries according to the markings in the battery compartment The wrong polarity can damage the weather station y Damage that has occurred by careless handling is not covered by the warranty Producti...

Страница 2: ...onal but only one y Save the data when batteries is changed y Operates on 5x LR6 AA alkaline batteries not included Contents y Main unit Display unit y Outdoor unit LCD Display The following illustrat...

Страница 3: ...ture 14 Indoor humidity high alarm and low alarm 15 Indoor humidity 16 Rainfall unit 17 Outdoor temperature high alarm and low alarm 18 Outdoor temperature 19 Outdoor reception signal 20 Outdoor Humid...

Страница 4: ...ro sensor 4 Rain collector 5 Bubble level 6 Solar panel 7 Antenna 8 U Bolt 9 Battery compartment 10 Reset button 11 LED Indicator lights for 4 seconds when the unit powers up Then the LED will flash o...

Страница 5: ...e the other side is bent at a 90 degree angle and has a curved profile which will end up hugging the mounting pole Once the metal plate is inserted insert both U bolts through the respective holes of...

Страница 6: ...ly There should be no noticeable friction when it is turning Figure 5 Wind speed cup installation diagram 3 Install wind vane Push the wind vane onto the shaft on the opposite side of the wind cups un...

Страница 7: ...crewdriver and insert 2 AA batteries in the battery compartment The LED indicator on the back of the sensor package will turn on for four seconds and then flash once every 48 seconds indicating sensor...

Страница 8: ...tailed in this section you may want to skip to the setup instructions first while you keep the assembled outdoor sensor package nearby although preferably not closer than 5 ft from the console This wi...

Страница 9: ...just the mounting pipe as necessary If the bubble is close but not quite inside the circle and you cannot adjust the mounting pipe you may have to experiment with small wooden or heavy cardboard shims...

Страница 10: ...Frequency Interference RFI If you have other 433 868 915 MHz devices and communication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the tra...

Страница 11: ...itter the radio reception icon will be turned on Do not press any key before outdoor sensor data received otherwise the outdoor sensor learning mode will be terminated When outdoor transmitter has bee...

Страница 12: ...receiver and transmitter in the open field can reach a distance of up to 330 feet providing that there are no interfering obstacles such as buildings trees vehicles high voltage lines etc Radio interf...

Страница 13: ...de Setting Mode Press the SET key for 2 second while in normal mode to enter the Setting mode LCD contrast digits will start flashing You can skip over any setting by press the SET key Press key or MI...

Страница 14: ...0 75 to 1 25 y History rainfall Calibration y Outdoor humidity Calibration y Outdoor temperature Calibration y Indoor humidity Calibration y Indoor temperature Calibration Wind Speed Calibration Wind...

Страница 15: ...hours Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer Humidity Calibration Humidity is a difficult parameter to measure accurately and drifts ov...

Страница 16: ...reset The total is multiplied by 0 3 to get a total in mm This is then converted to inches if necessary by multiplying by 0 0393700787 The calibration multiplier is then applied to this and this is t...

Страница 17: ...arm 1 99 8 Outdoor temperature high alarm 40 C 60 C 9 Wind chill high alarm 40 C 60 C 10 Dew point high alarm 40 C 60 C 11 Indoor humidity high alarm 1 99 12 Indoor temperature high alarm 9 9 C 60 C I...

Страница 18: ...tion was activated again within 3 hours alarm will not sound but will continue to flash until weather conditions have become more steady This feature is useful to avoid repeated triggering for the sam...

Страница 19: ...time and date at which these values were recorded if hold the SET key for 3s in the following individual minimum value will be reset to current reading together with the current time and date 1 Outdoo...

Страница 20: ...ide range Accuracy 1m s wind speed 10m s 10 wind speed 10m s Measuring interval thermo hygro sensor Water proof level Indoor data Measuring interval temperature humidity Indoor temperature range if ou...

Страница 21: ...eed to change the transmitter batteries The low battery indicator will work normal when the outdoor temperature rise to 10 35 21 Maintance 1 Clean the rain gauge once every 3 months Rotate the funnel...

Страница 22: ...is required Do not dispose of these items with general household waste Separate for the treatment recovery and recycling of the materials used Waste batteries can be returned to any waste battery rec...

Отзывы: