![PRO SIGNAL PSG04173 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/pro-signal/psg04173/psg04173_manual_1604563005.webp)
6
5.2.1 Install U-bolts and mounting pole
Installation of the U-bolts, which are in turn used to mount the sensor
package on a pole, requires installation of an included metal plate to
receive the U-bolt ends. The metal plate, visible in Figure 1, has four
holes through which the ends of the two U-Bolts will fit. The plate itself is
inserted in a groove on the bottom of the unit (opposite side of solar
panel). Note that one side of the plate has a straight edge (which goes
into the groove), the other side is bent at a 90-degree angle and has a
curved profile (which will end up “hugging” the mounting pole). Once the
metal plate is inserted, remove nuts from the U-Bolts and insert both
U-bolts through the respective holes of the metal plate as shown in
Figure 8.
Figure 1
Loosely screw on the nuts on the ends of the U-bolts. You will tighten
these later during final mounting. Final assembly is shown in Figure 9.
Figure 2
The plate and U-Bolts are not yet needed at this stage but doing this
now may help avoid damaging wind vane and wind speed cups later on.