background image

9

WIRE DIAGRAM, CG/GR, 10/14, 120V/230/240V, WITH TIMER

STAR MANUFACTURING INTERNATIONAL, INC.

MODEL: SEE ABOVE

SK2001       REV.  C         12/12/2005

DR: PMR

B

A

C D

GREEN

BLACK

WHITE

NORTH AMERICA:

15 AMP PLUG

NEMA 5-15P ON 120V, 1,800 WATT UNITS FOR U.S. ONLY.

NEMA 5-15P ON 120V, 1,400 WATT UNITS FOR U.S. AND CANADA.

NEMA 6-15P ON ALL 240V, 1,800 WATT UNITS.

20 AMP PLUG

NEMA 6-20P ON ALL 240V, 3,600 WATT UNITS.

NEMA 5-20P ON 120V, 1,800 WATT UNITS FOR U.S. AND CANADA.

TOP ELEMENT

TRANSFORMER

TERMINAL BLOCK

FOR REFERENCE

WIRING DIAGRAM IS SHOWN AS UNIT IS ASSEMBLED
WITH THE BOTTOM PLATE REMOVED.  ITEMS ARE IN 

GENERAL LOCATION BUT MAY BE RELOCATED OR SCALED 

FOR CLARITY.

3

E2 E1

8

8

1

1

11

12

12

11

5

2

5

2

4

4

10

10

9

9

13

13

3

3

7

6

6

7

INDICATOR LIGHT

(POWER ON)

TIMER BOARD

SWITCH

THERMOSTAT

BOTTOM ELEMENT

20

19

18

G

UNITS WITH IEC CONNECTOR:

POWER INLET CONNECTOR:

IEC 320 C-20 POWER INLET, ON ALL 208 - 240V UNITS.

FOR USE WITH DETACHABLE CORDSETS SUPPLIED

WITH A STRAIGHT, FEMALE, IEC 60320 C-19 CONNECTOR.

L

N

E

REAR OF CONNECTOR SHOWN.

 CERTAIN INSTANCES MAY NOT BE AVAILABLE

ILLUSTRATIVE PURPOSES ONLY AND IN

SOME ITEMS ARE INCLUDED FOR

Содержание 9D-GR10T4K-UK

Страница 1: ...1 TABLE TOP TWO SIDED TOASTER MODEL 9D GR10T4K UK Installation and Operation Instructions 2M Z9364 Rev 1 24 2006 ...

Страница 2: ...dures policies and regulations the specifications contained in this sheet are subject to change without notice While Star Manufacturing exercises good faith efforts to provide information that is accurate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in...

Страница 3: ...d internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms VENTILATION AND CLEARANCES The installation of any components such as a vent hood grease extractors and or fire extinguishing systems must conform to their applicable nationally recognized installation standards and or local building codes ELECTRICAL CONNECTION CAUTION Before maki...

Страница 4: ...3 200 F 93 C 4 250 F 121 C 5 300 F 148 C 6 350 F 176 C 7 400 F 204 C 8 450 F 232 C 9 500 F 260 C 10 550 F 287 C PROGRAMMING THE TIMER The timer may be factory pre set If changes are required follow these steps 1 Press and hold the PGM button located on the left side of the display 2 Press and hold one of the buttons 1 through 4 that needs to be programmed After approximately 1 second the display w...

Страница 5: ...tton 1 through 4 used to start the countdown NOTE If one wants to end a countdown the same button 1 through 4 can be pressed at any time in the countdown cycle The display will return to the programmed time for that button 7 Raise the lid to the open position and remove the product s 8 For best performance keep the lid closed when products are not being cooked OPERATING HINTS AND SAFETY Disconnect...

Страница 6: ...ldupoccurs useacarbonremovalagentaccordingtotheinstructionsprovided with the cleaner When this process is complete you must re season the grill according to your company corporate guidelines or the seasoning instructions in this manual CAUTION DO NOT IMMERSE OR LET THE UNIT STAND IN WATER DO NOT HOSE DOWN THE UNIT OR THE TABLE COUNTER ON WHICH THE UNIT IS LOCATED KEEP AWAY FROM RUNNING WATER CAUTI...

Страница 7: ...rrect position 4 Check that the thermostat is set to the proper temperature B The top platen is not heating 1 Check that the switch is in the correct position C The counter balance roller is not rolling 1 Clean the rollers If the unit still does not operate contact the factory one of its authorized representatives or a local service company for service or required maintenance ...

Страница 8: ...ve cleaners This warranty does not apply to the non stick properties of such materials This warranty is not valid on Conveyor Ovens unless a start up check out has been performed by a Factory Authorized Technician In order to make a claim under this warranty a warranty report must be filed with Star Manufacturing International Inc in St Louis Missouri U S A by the dealer distibutor through which pr...

Страница 9: ...TRANSFORMER TERMINAL BLOCK FOR REFERENCE WIRING DIAGRAM IS SHOWN AS UNIT IS ASSEMBLED WITH THE BOTTOM PLATE REMOVED ITEMS ARE IN GENERAL LOCATION BUT MAY BE RELOCATED OR SCALED FOR CLARITY 3 E2 E1 8 8 1 1 11 12 12 11 5 2 5 2 4 4 10 10 9 9 13 13 3 3 7 6 6 7 INDICATOR LIGHT POWER ON TIMER BOARD SWITCH THERMOSTAT BOTTOM ELEMENT 20 19 18 G UNITS WITH IEC CONNECTOR POWER INLET CONNECTOR IEC 320 C 20 PO...

Страница 10: ...DO NOT TOU CH PE LI GR O PE LI GR O corri ente de agua corri ente de agua SUP ERIF ICIE SUP ERIF ICIE FAVO R NO TOCA R FAVO R NO TOCA R CALI ENTE CALI ENTE PR EC AU CIO N PR EC AU CIO N Maint engas e lejos de Maint engas e lejos de ma ng ue ra ma ng ue ra No roc ia con No roc ia con o dejar que la base este o dejar que la base este estan cada sobre agua estan cada sobre agua Favo rde no sume rgir ...

Страница 11: ...15 10V 6VA 21 2R Z2907 1 COUNTER BALANCE 10 IRON 22 D9 Z2774 1 BOTTOM INSULATION RETAINING PLATE 10 23 D9 Z2908 1 INSULATION 10 24 D9 Z2773 1 BOTTOM ELEMENT RETAINING PLATE 10 25 2N Z1979 1 ELEMENT HEATING 1000W 120V BOTTOM 26 2F Z1929 1 CASTING SMOOTH BOTTOM 10 ALUMINUM 27 D9 Z2772 1 TOP ELEMENT INSULATED PLATE 10 28 D9 GR0084 1 TOP RETAINING PLATE ASSEMBLY 10 29 B9 04 WB 0046 1 CLAMP WIRE SUPPOR...

Страница 12: ......

Отзывы: