© Pro-Ject Audio Systems · VC-S2 ALU (from S/N:19F011632) · Revision 2019.10.19

 

 

 

 

1.

 

Disconnect the mains cable 

2.

 

Remove ventilation outlet grille (4) 

3.

 

Place the drain insert spout into the hole (drain insert is included in the accessories) and 

make sure it sits there tightly, so no fluid can reach the inside of the device. 

4.

 

Lift the opposite side of the VC-S2 ALU up to drain the unit reservoir to a big container. 

5.

 

Remove the spout and attach the ventilation outlet grille back to its place. 

 

 

 

Regularly check the velvet strips on the arm. Make sure they are clean, no dirt or debris is present.  
 

 

Prior to maintenance, always disconnect the record cleaning machine from the power outlet! 

 

Technical specifications Vinyl Cleaner VC-S2 ALU 

Nominal speed 

30 r.p.m. 

Power consumption 

230V/800W, 120V/650W 

Dimensions (W x D x H) 

415 x 325 x 272 mm (fully assembled) 

Weight 

8kg (netto) 

Fuse  

T6,3A 

 

 

Potential incorrect use and fault conditions 

Pro-Ject  products  are  manufactured  to  the  highest  standards  and  undergo  strict  quality  controls 

before  leaving the factory.  Faults that may possibly  occur  are  not necessarily  due  to material  or 

production faults but can sometimes be caused by incorrect use. Some of these faults are as follows: 

 

The platter doesn't turn although the unit is switched on: 

 

The power cord is not connected to the unit. 

 

The power cord is not plugged in to the AC wall outlet. 

 

Broken fuse in the main switch.  

 

Overheating protection is active. 

 

Top clamp plate is not tightened properly. 

How to adjust the height of VC-S2 ALUs record clamp      

The VC-S2 ALU is pre-adjusted to spec for standard 80 

 180 g records. There is enough headroom, 

so that the arm is optimally pressed against the record and the cleaning fluid can be completely 

removed. The vacuum arm works best when it is parallel to the record when operating and the adhesive 

strips is pressed gently on the surface of record. If the vacuum suction arm is not in the correct distance 

from the record it may not be able to completely vacuum the cleaning fluid. In this case it may be 

necessary to adjust the height of the clamp. You will need a Phillips screwdriver (to unscrew the set 

screw of the clamp base part) and a 2.5mm hexagon key (to loosen motor spindle): 

1.

 

Disassemble the clamp (2) by unscrewing the set screw (3) from the motor flange spindle (11)  