background image

© Audio Trade GmbH · Pro-Ject 6 Perspe

X

 · Revision 1.11.08/1.1.09

 

 

6

Connection to the amplifier

 

The record player has gold plated female RCA phono sockets (14) so you can substitute the interconnect 
cables supplied with those of your choice for connection to the amplifier if you wish. Your dealer can advise 
you on alternative cables. Use the Phono input (sometimes labelled gram, disc or RIAA) on your amplifier. 
Make sure that the phono input offers correct matching and amplification for the type of cartridge used. Line 
inputs (such as CD, Tuner, Tape or Video) are not suitable. 
Take care to connect the left and right channels correctly. The right channel is usually marked red, the left 

channel black or white. Check the manual supplied with your amplifier for relevant information. An earthing 
wire may be connected to the screw terminal between the sockets if you encounter hum problems when using 
the record player. 
If your amplifier does not have an input suitable for phono cartridges you will require a separate phono 
amplifier stage for MM or MC cartridges such as the PRO-JECT PHONO BOX or the PRO-JECT TUBE BOX 
which is then connected between the record player and a free line level input of the amplifier. 
For detailed product information please refer to the Pro-Ject web site 

www.project-audio.com

.

 

Mains power connection, switching on and off 

The turntable is supplied with a power supply suitable for your country's mains supply. Check the label before 
connecting to ensure compliance with the mains rating in your house. Connect the low voltage plug from the 
power supply to the record player's motor before connecting the power supply to the mains. Pressing the 

power switch (20) alternately starts or stops the motor.

 

Fitting the lid 

Fit the lid (dust cover 10) carefully over the hinge prongs and adjust the screws (12) until the lid stays open 
where you want it to without being too stiff to open or close. 

Maintenance and cleaning 

Your record player requires little or no regular maintenance. Remove dust with a slightly moistened antistatic 

cloth. Never use a dry cloth because this will create static electricity which attract more dust! Antistatic 
cleaning fluids are available at specialist stores but must be applied sparingly to avoid damage to rubber 
parts. It is recommended to fit the needle cover before cleaning or maintenance is carried out to avoid damage. 
If the player is not used over a long period of time the drive belt can be removed to prevent unequal stretching. 

!

 

Always disconnect the record player from the mains power supply as a precaution before maintenance! 

Useful tips 

The lid is not only a dust cover but also a resonant structure likely to be excited by, and to pass into the 
plinth, the acoustic energy emanating from your loudspeakers during replay. It is therefore recommended 
that the lid be removed for optimum sound quality. 
The record player should be positioned on a low-resonance surface such as wood or multiple layer ply board 

to avoid structural vibrations disturbing replay.

 

Technical specifications  PRO-JECT 6 Perspe

X

 

Nominal speeds * 

33,33/45,11 r.p.m. 

Speed variance 

±0,5% 

Wow and flutter 

±0,06% 

Signal to noise 

-73dB 

Downforce range 

15-30mN 

Effective tonearm length 

9 " (230mm) 

Overhang 18mm 
Power consumption 

2W 

Outboard power supply 

16V/500mA AC, suitable for your country's mains supply 

Dimensions (W x H x D) 

460 x 160 x 365mm, dust cover open 460 x 420 x 465mm 

Weight 10,5kg 

Содержание Pro-Ject 6 PerspeX

Страница 1: ...INSTRUCTIONS FOR USE Pro Ject 6 PerspeX...

Страница 2: ...Audio Trade GmbH Pro Ject 6 PerspeX Revision 1 11 08 1 1 09 2 A B C 14 14 14 17 16 11 11 12 10 22 11 11 3a 13 3 2 20 4 5 1 1 1 21 9 7 6a 15 6 18 8 24 23 9a...

Страница 3: ...e feet with anti scratch cups 23 Motor unit with Sorbothane pad 24 Sub chassis A B C Knurled sub chassis levelling screws Screw down record clamp not shown Connection cable not shown Power supply not...

Страница 4: ...the original packaging so they are available for any future transportation Fitting and connecting the cartridge All cartridges with half inch mounting holes can be fitted Leaving the needle s protect...

Страница 5: ...r to the cartridge body which is often the case Slacken off the screw just enough to be able to revolve the arm tube without applying force Note Do not remove the screw completely Screw With the aid o...

Страница 6: ...before connecting the power supply to the mains Pressing the power switch 20 alternately starts or stops the motor Fitting the lid Fit the lid dust cover 10 carefully over the hinge prongs and adjust...

Страница 7: ...thout oil dirty or damaged Service Should you encounter a problem which you are not able to alleviate or identify despite the above information please contact your dealer for further advice Only when...

Страница 8: ...de GmbH Pro Ject 6 PerspeX Revision 1 11 08 1 1 09 8 Please remove feet bevore repacking Counter weights 3 Subchassis transport locks Accessories Power supply Motor with black cover Platter Feet Platt...

Отзывы: