background image

9

Place all parts of the hydrotherapy spa in a cleared area and remove the packing materials. Do not dispose
of the packing materials until assembly is completed.  

Assembly requires your own phillips screwdriver                          .

1.

Before beginning assembly, make sure that you
have read and understand the information above
and on the previous two pages.

Remove the eight #10 x 2” Machine Screws (37) that
secure the indicated Access Panel (25) to the spa.
Carefully remove the Access Panel until the CD wire
harness (not shown) is visible and disconnect it. Set
the Access Panel aside. 

Be careful not to damage

the spa shell.

Insert the Pillow (38) into the lounge seat receptacle.
Note: The Pillow can be rotated 180º and reattached
in a high or low position.

Assembly

25

37

37

1

38

2. Close the valve knob on the drain hose. Thread the

cap onto the drain hose.

Locate the four gate valves inside the access open-
ing (there are two gate valves per pump). Turn the
gate valves counterclockwise to open them.

Make sure that the six collars are tightened (there
are two collars per pump and two on the heater).

See step 1. Reconnect the CD wire harness to the
CD Player and reattach the Access Panel (25) to the
spa.

Collar

Cap

Valve

Knob

Drain

Hose

2

Gate Valve

Содержание MAGNUM PFSB53950

Страница 1: ...t line will provide immediate assistance free of charge CUSTOMER HOT LINE 1 888 884 6555 Mon Fri 8 a m 5 p m CST Model No PFSB53950 Serial No The serial number is on a sign behind the access panel Wri...

Страница 2: ...shooting 20 Part List 22 Exploded Drawing 23 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible t...

Страница 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Страница 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Страница 5: ...NING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted w...

Страница 6: ...or your benefit read this manual carefully before using the hydrotherapy spa If you have questions after reading the manual please call our Customer Service Department toll free at 1 888 884 6555 Mond...

Страница 7: ...he spa provided you leave access to the motor for service 9 Make sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Страница 8: ...or conduit within five feet of the spa Three options for wiring the spa are shown at the right A wiring diagram is also found on the inside of the electronics pack for reference Option 1 Main Panel GF...

Страница 9: ...ible and disconnect it Set the Access Panel aside Be careful not to damage the spa shell Insert the Pillow 38 into the lounge seat receptacle Note The Pillow can be rotated 180 and reattached in a hig...

Страница 10: ...s at the level of the molded fill line Do not overfill the spa See the inset drawing Set the Filter 5 and the Basket 22 in the filter housing Next place the Filter Cover 3 in the filter housing 4 Pull...

Страница 11: ...A countdown from 005 to 000 will appear in the display of the console Once the countdown has reached 000 Pr will be displayed Pr indicates that the controller is in the two pump priming mode This mod...

Страница 12: ...hould resume normal operation If the spa continues to run after the test button is pressed the GFCI is damaged Do not use the spa until the GFCI has been repaired or replaced by a qualified electricia...

Страница 13: ...uction covers should always be in place over the fittings Never operate the spa with out the suction covers in place F The ozone generator helps sanitize the spa with minimal chemical treatment during...

Страница 14: ...e spa to within 20 F of the set temperature during the filter cycles only Slp is always displayed when the actual temperature does not equal the set temperature Slp alternates with the actual temperat...

Страница 15: ...the temperature set ting of the water The temperature setting can be from 80 F to 104 F The startup temperature is set at 100 F The water heats at about 6 F per hour with the cover on Use a medical or...

Страница 16: ...AINING THE SPA EXTERIOR The surround is maintenance free The surround should be cleaned with a mild soap solution do not use solvents or waxes CLEANING THE SPA SHELL The spa shell should be cleaned wi...

Страница 17: ...t unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused by improper pH levels is not covered under the warranty To maintain the p...

Страница 18: ...f time The spa must always be drained before major repairs are made The hydrotherapy spa should always be covered when it is empty Direct sunlight can cause exten sive damage The surface of the spa sh...

Страница 19: ...over each jet starting with the highest jet and fin ishing with the lowest jet 5 Set the air controls to the highest setting and repeat step 3 6 Drain the pumps see DRAINING THE PUMPS on this page Onc...

Страница 20: ...Set the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for th...

Страница 21: ...s on the floor around the hydrotherapy spa the spa shell may have a leak Contact your local pool and spa service provider for repairs 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHU...

Страница 22: ...4 Washer 32 1 Face Plate 33 6 Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet 36 2 Drain Plug 37 48 10 x 2 Machine Screw 38 2 Pillow 39 2 Drain Plug O ring 40 4 Corner Panel 41 2 Neck Jet 42 1 F...

Страница 23: ...7 37 37 33 9 38 14 9 9 41 41 43 43 40 7 8 34 34 1 44 42 5 3 24 2 13 19 28 23 31 13 6 36 39 23 31 4 13 10 28 13 6 36 39 23 31 23 31 4 31 9 9 31 46 9 31 31 31 31 22 37 37 48 49 50 51 47 38 Exploded Draw...

Страница 24: ...idents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting from imprope...

Отзывы: