Memo
Страница 1: ...PL X900 Series Standard Display PL DU6900 PL DU7900 User Manual...
Страница 2: ...gital Electronics Corporation shall not be held liable by the user for any damages losses or third party claims arising from the uses of this product All Company Manufacturer names used in this manual...
Страница 3: ...ential Safety Precautions System Design Before connecting the DU s power cord terminals to its terminal block be sure the power cord is disconnected from the power supply Do not use power that is beyo...
Страница 4: ...disconnect the DU unit s power cord immediately and contact your local DUdistributor Read and understand Chapter 4 Installation and Wiring thoroughly before selecting an installation location for the...
Страница 5: ...function Avoid restricting the DU s naturally occuring ventilation or storing or using the DU in an environment that is too hot Do not store or use the DU where chemicals and acids evaporate or where...
Страница 6: ...fected Displaying a single screen image for long periods of time can cause an afterim age to remain on the screen To correct this turn the unit OFF for 5 to 10 minutes then ON again This phenomenon is...
Страница 7: ...em Design 1 1 1 1 1 RS 422 and USB Connections 1 2 1 1 2 Connecting the Dual Displays 1 3 1 2 Accessories 1 5 CHAPTER 2 SPECIFICATIONS 2 1 General Specifications 2 1 2 1 1 Electrical 2 1 2 1 2 Environ...
Страница 8: ...llation Positioning Cautions 4 1 4 1 3 Shock Vibration Related Cautions 4 1 4 2 DU Installation 4 2 4 2 1 Installation 4 2 4 3 Wiring Cautions 4 5 4 3 1 Connecting to PL 4 5 4 3 2 Connecting the Power...
Страница 9: ...useful or important supplemental information PL Refers to all BOX Type Industrial Computers PL B900 and PL B910 Series models DU Refers to all standard Displays PL DU6900 PL DU7900 The list below desc...
Страница 10: ...f usage options for all your applications Easy Front Panel Installation The PL is designed to be installed easily into the front of any panel or device It is also rugged enough for use in harsh indust...
Страница 11: ...12 set Power Cord 1 for AC100V AC115V DU Unit 1 PL DU6900 T42 PL DU7900 T42 Package Contents PL X900 SERIES STANDARD DISPLAY PL DU6900 PL DU7900 USER MANUAL English 1 This manual PL X900 SERIES STAND...
Страница 12: ...te for the current and voltage used 0 75mm2 or larger When installing the DU to a metal panel or cabinet be sure to design the DU s power cut off switch as a separate device that is within easy reach...
Страница 13: ...et be sure to design the DU s power cut off switch as a separate device that is within easy reach by the unit s operator There is a danger of explosion if the DU s backup battery is incorrectly replac...
Страница 14: ...will differ DU TFT Color LCD Touch Panel PL B900 PL B910 Series Unit Display Unit s Reset Button PL USB Front Access Unit PL US200 Screen Protection Sheet PL CS100 Connection Cable PL CB200 10M PL CB2...
Страница 15: ...the power OFF before turning it ON again Be sure to use only the OS types shown here with each cable If a different type OS is used the utility software drivers etc is not supported Dip Switch Setting...
Страница 16: ...one PL unit There are two types of installation methods to use the Star Method or the Daisy Chain Method Star Method With the Star Method the Display Expansion Board is installed in the PL and both di...
Страница 17: ...following points The PL unit is a PL B910 series unit PL B910 or PL B911 The Touch Panel connection cable should be a USB cable The operating system is Windows 98 Second Edition Set the PL and DU s di...
Страница 18: ...ard PL CB200 5M Connects Standard Displayand Main Unit 5m USB Front Access Unit PL CB200 10M Connects Standard Displayand Main Unit 10m Used onlywith RS 422 connection Maintenance Items These optional...
Страница 19: ...PL unit For a list of the USB units that can be used with your PL please contact your local PL distributor When using USB type devices be sure they are USB compatible and be sure to read that device s...
Страница 20: ...s Chapter 2 Specifications 1 General Specifications 2 Functional Specifications 3 Names and Functions of DU Parts 4 Display Unit Dimensions 2 1 2 Environmental Ambient Operating Temperature Storage Te...
Страница 21: ...to installing the DU be sure to confirm the type of conditions that will be present in the DU s operating environment If the installation gasket is used for a long period of time or if the unit and it...
Страница 22: ...228 1mm 11 97in X 8 98in Colors Brightness Control Not Available Available Contrast Control Backlight Backlight Lifetime time required for brightness to fall to half its normal level 25 000 hours at...
Страница 23: ...s Can be used for PL DU7900 only I Power Switch Turns ON OFF the DU s power supply J Power Terminals The DU s AC100V 240V power cord termi nals are connected here K USB Connector USB I F USB 1 0 compa...
Страница 24: ...L DU6900 External Dimensions 2 4 2 PL DU7900 External Dimensions Top View 346 13 62 287 11 30 63 2 48 14 0 55 31 1 22 271 10 67 330 12 99 Front View Side View Unit mm in Main Unit Only Top View 374 14...
Страница 25: ...s installation panel or allowing water to enter inside Be sure the thickness of the panel is from 1 6mm 0 06in to 10mm 0 39 in Depending on material used for panel surface you may need to strengthen t...
Страница 26: ...about the installation of other option units please refer to those unit s individual Operation Instructions To avoid electric hazards be sure to turn the PL s power OFF before installing any optional...
Страница 27: ...attachment screws and slide the Rear Part upwards Be sure to place the DU unit on a flat lever surface prior to install ing the PL PE200 This will prevent damage to the DU and the acci dental cutting...
Страница 28: ...l 3 Remove the Rear Cover and expose the interior of the DU Front Panel see Fig A 4 Loosen the Side Cover s screw and push the Front Panel s Slide in the direction shown to release it See Fig B Then t...
Страница 29: ...n step 5 and secure the unit in place 7 Reattach the Rear Cover to the Front Panel using the four 4 attachment screws removed in step 3 Since the PL PE200 con tains precision parts be sure to handle i...
Страница 30: ...SB Front Access Unit PL US200 Use the following procedure to install the PL US200 in the DU 1 Unscrew the blank panel s three 3 attachment screws and remove the DU rear face s PL US200 blank panel 2 U...
Страница 31: ...PL US200 cable s black Rubber Stopper in the DU rear panel s notch Then re place the PL US200 s rear blank panel rotating it 180 from its original orientation and secure it in place with its three 3...
Страница 32: ...n the location shown in the left side drawing If this area s temperature exceeds the allowed limit a machine breakdown can occur Temperature Sensor 0 o C to 50 o C 100mm Front face of DU 30mm Also be...
Страница 33: ...of the DU when designing the panel Be sure the gasket is in place before installing the DU Panel Cut Out 1 6mm to 10 0mm It is strongly recommended that you use the gasket Place the DU on a level sur...
Страница 34: ...than 30o from vertical OK OK OK Avoid placing the DU next to other devices that might cause overheating Avoid using the DU where the ambient temperature will exceed 50 C Keep the DU away from arc gen...
Страница 35: ...fasteners hook on 3 Slide the fastener backwards until it stops Attachment Hole Top Bottom View PL DU7900 Side View both sides PL DU6900 Side View both sides 2 Insert each fastener into its attachment...
Страница 36: ...ls pro vides AC100V to 240V power L Live and N Neutral This terminal is connected to the DU s frame chassis screw size M3 PL DU6900 1 Confirm that the DU s power switch is turned OFF Then remove the p...
Страница 37: ...the DU This power cord is designed only for AC100V AC115V use Be sure to use a different cable when using other than AC100V AC115V power 3 Reattach the terminal strip s transparent cover and secure it...
Страница 38: ...DU I O devices and power supply devices separately To improve noise immunity it is recom mended to attach a ferrite core to the power cord Isolate the main circuit high voltage large current line I O...
Страница 39: ...is recommended DU Other device DU Other device Other device DU c Shared ground not allowed a Dedicated Ground best 1 Set up a dedicated ground when using the rear panel s FG terminal b Shared Ground...
Страница 40: ...ning the Display Chapter 5 Maintenance 1 Regular Cleaning 2 Changing the Backlight 3 Periodic Check Points Use the optional Screen Protection Sheet when using the DU in extremely dirty or dusty areas...
Страница 41: ...enever changing the backlight be sure the DU s power cord has been disconnected When the DU s power has just been turned OFF the back light area is still very hot Be sure to wear gloves to pre vent be...
Страница 42: ...attachment screws and remove it 3 Remove the DU s four chassis attachment screws 4 Hold both sides of the DU s front panel section and use your thumbs to slide push the chassis forward in the directio...
Страница 43: ...nt screws Remove these 4 screws Use an 0 sized Phillips screwdriver to remove the back light attachment screws Be careful not to lose any of the small at tachment screws Do not let any of at tachment...
Страница 44: ...en release each plastic cable holder Each backlight uses a cable holder to prevent the cable from becoming caught or pinched when the DU s rear cover is opened or closed Be sure both cables are se cur...
Страница 45: ...w backlights with the metal clips 11 After installing both new backlights using steps 9 to 10 replace and tighten all attachment screws total of 4 screws Then re connect both board power connectors 12...
Страница 46: ...or closed Be sure both cables are secured by their holder before closing the rear cover Use a 1 sized Phillips screwdriver to remove the backlight attach ment screws Be careful not to lose any of the...
Страница 47: ...f not the DU may be damaged 10 Remove each backlight unit 11 Insert each new backlight 12 After installing both new backlights using steps 9 to 11 replace and tighten all backlight and LCD panel attac...
Страница 48: ...RH Is the operating atmosphere free of any corrosive gasses Electrical Specifications Is the input voltage appropriate AC85V to AC265V 50 60Hz Related Items Are all cables connected properly Have any...
Страница 49: ...Memo...
Страница 50: ...Grounding 4 8 H Hardware Reset Switch 2 4 I Icon Meaning 2 Insert the DU into the Installation Slot 4 3 Installation 3 1 Installation and Wiring 4 1 Installation Cautions 4 1 Installation Gasket 4 2 I...
Страница 51: ...U 5 R Regular Cleaning 5 1 S Securing the Installation Fasteners 4 4 Shock Vibration Related Cautions 4 1 Specifications 2 1 Status LED 2 4 Structural Specifications 2 2 System Design 1 1 T Table of C...