Countermeasures Against 

Hard Disk Problems 

To ensure safe use of the product, Pro-face 
has taken the following measures to cope 
with possible problems. 

(1) Hard disk drive unit provides shock-

absorbing structure.
To minimize influence of impact, the 
hard disk drive unit is protected with 
shock-absorbing rubber. 

(2) Recommendation of Windows

®

 XP 

Embedded OS
Windows

®

 XP Embedded OS pre-

installed CF cards are commercialized 
for more environmentally-enhancing 
system.

(3) Soft mirror (Option)

The optional soft mirror function can 
duplicate system data to prevent data 
loss. 

(4) Cartridge type (Specified models only)

Availability of cartridge type hard disks 
allows you to exchange the hard disk 
drive unit easily, if a problem occurs.

(5) Hot-swap function in hard disk drive 

units
When the hot-swap function is used with 
the soft mirror function, hard disks with 
problems can be exchanged while the 
system is in operation.

Hard Disk Installation / 

Replacement

To prevent damage and injury, take the 
following precautions when installing or 
replacing hard disks.

(1) Do not install or replace hard disk drive 

units while power is supplied to the sys-
tem. (Hard disk drive units can be 
installed or replaced when the soft mirror 
function is used with the hot-swap func-
tion.)

(2) Since hard disks are vulnerable to 

vibration or impact, they must be 
handled carefully.

(3) Hard disks are electronic components. In 

installation or replacement of hard disks, 
take a countermeasure against static 
electricity. (e.g. Wearing an earth-band 
or a ground strap)

(4) Do not touch the metal cover on the disk 

surface. Touching it may cause a failure.

Содержание hard disk

Страница 1: ...vibration and operation time it is regarded as a consumable component The incidence of problems may increase depending on the operating conditions even within the maintenance period To maintain the st...

Страница 2: ...h may result in system shutdown To avoid this problem make the settings for the power saving function of Windows so that the hard disk motor can stop for the specified time The rotation of the hard di...

Страница 3: ...sk life span because the allowable head loading unloading frequency is 600 000 times Even if the hard disk has not reached the end of its life span the hard disk operation may become unstable due to i...

Страница 4: ...used in a system that may vibrate during operation Never attempt to move the system with the panel computer power supply turned ON 1 Keep any system or control panel that includes this product free f...

Страница 5: ...rce directly into the air hole of the hard disk Such an action rapidly changes the internal pressure and easily causes the above phenomenon For Protection of the Hard Disk 1 Scan disk or error check r...

Страница 6: ...if a problem occurs 5 Hot swap function in hard disk drive units When the hot swap function is used with the soft mirror function hard disks with problems can be exchanged while the system is in oper...

Страница 7: ...and other countries Copyright 2007 Digital Electronics Corporation All rights reserved Inquiry Do you have any questions about difficulties with this product Please access our site anytime that you ne...

Отзывы: