Pro-face GP-3500L Скачать руководство пользователя страница 31

3.5 Transfer the screen data to GP-4501T/TW 
Transfer the project file after the display unit type change to GP-4501T/TW. 
You can transfer data to GP-4501T/TW via; 
 

 

A USB transfer cable (model: CA3-USBCB-01) 

 

A USB data transfer cable (model: ZC9USCBMB1) 

 

A commercial USB cable (USB Type A/mini B) 

 

A SD card/A USB storage device 

 

Ethernet 

 
But, this section explains, as an example, how to transfer screen data with a USB 
transfer cable (model: CA3-USBCB-01). 

 

 

 

 

 

 

 

 

 

 

  

31/49

 

Содержание GP-3500L

Страница 1: ...Easy Smooth GP ST 3500 Series GP4000 Series Replacement Guidebook 1 49 Fourth Edition Apr 2012 Copyright 2012 4 Digital Electronics Corporation All Rights Reserved...

Страница 2: ...power supply type of the model you use When replacing AC power supply type AGP3500 S1 AF When replacing DC power supply type AGP3500 S1 D24 The power supply type is AC but the panel cutout dimensions...

Страница 3: ...ries 5 7 4 GP 4400 series 7 5 7 0W 5 GP 4500 series 10 4 A 6 GP 4600 series 12 1 01 RS 232C 422 485 B 03 RS 485 isolation T TFT color LCD C W TFT color LCD Wide Type A Analog Resistive Film Touch Pane...

Страница 4: ...R 14 CONNECTOR LOCATIONS ON GP 3500S ST 3500T AND GP 4501T 14 CONNECTOR LOCATIONS OF GP 3500S L ST 3501C AND GP 4501TW 16 2 2 TOUCH PANEL SPECIFICATIONS ONLY WHEN REPLACING WITH GP 4501T 17 2 3 DISPLA...

Страница 5: ...GP ST 3500 SERIES 25 3 4 CHANGE THE DISPLAY UNIT TYPE 30 3 5 TRANSFER THE SCREEN DATA TO GP 4501T TW 31 3 6 DIFFERENCES OF SOFTWARE 35 CHAPTER 4 COMMUNICATION WITH DEVICE PLC 36 4 1 DRIVER LIST 36 4 2...

Страница 6: ...nal Dimensions mm 313 W 239 H 56 D 272 5 W 214 5 H 57 D Touch Panel Type Analog Analog Matrix See 2 2 Application 8MB 16MB UP 32MB Memory SRAM 320KB 320KB Backup Battery Secondary Battery Rechargeable...

Страница 7: ...SD Card I F NEW Type A USB I F Type mini B See 2 5 Printer I F USB Type A Auxiliary I O I F See 2 6 2 Expansion Unit I F See 2 7 3 7 49...

Страница 8: ...H 56 D 315 W 241 H 56 D Touch Panel Type Analog Application 8MB 16MB 16MB Memory SRAM 320KB 128KB Backup Battery Secondary Battery Rechargeable Lithium battery NEW Primary Battery Replaceable Lithium...

Страница 9: ...Type A USB I F Type mini B See 2 5 Printer I F USB Type A Auxiliary I O I F See 2 6 2 Expansion Unit I F See 2 7 3 9 49...

Страница 10: ...ons mm 313 W 239 H 56 D 315 W 241 H 56 D Touch Panel Type Analog Application 8MB UP 16MB Memory SRAM 320KB 128KB Backup Battery Secondary Battery Rechargeable Lithium battery NEW Primary Battery Repla...

Страница 11: ...Type A USB I F Type mini B See 2 5 Printer I F USB Type A Auxiliary I O I F See 2 6 2 Expansion Unit I F See 2 7 3 11 49...

Страница 12: ...70 5 W 212 5 H 57 D 272 5 W 214 5 H 57 D Touch Panel Type Analog Analog Matrix See 2 2 Application 6MB UP 32MB Memory SRAM 320KB 320KB Backup Battery Secondary Battery Rechargeable Lithium battery NEW...

Страница 13: ...mensions mm 270 5 W 212 5 H 57 D 315 W 241 H 56 D Touch Panel Type Analog Application 6MB UP 16MB Memory SRAM 320KB 128KB Backup Battery Secondary Battery Rechargeable Lithium battery NEW Primary Batt...

Страница 14: ...Chapter 2 Compatibility of Hardware 2 1 Locations of connector Connector locations on GP 3500S ST 3500T and GP 4501T GP 3500S ST 3501T GP 4501T 14 49...

Страница 15: ...put Terminal Bl er Connector DC type ock AC type Pow 2 Serial I F COM1 3 Serial I F COM2 4 Ethernet I F Ethernet I F 5 USB I F Type A 6 USB i B I F Type min 7 SD Card I F 8 CF Card I F 9 Ex pansion Un...

Страница 16: ...Connector locations of GP 3500S L ST 3501C and GP 4501TW GP 3500S L ST 3501C GP 4501TW 16 49...

Страница 17: ...he same time touch input of the coordinates located between those two points is recognized Take note of it There s a model number difference between the Analog type and the Matrix type For details see...

Страница 18: ...W the panel cutout dimensions get larger It s necessary to process the panel In other cases there s no change in the panel cutout dimensions 2 5 Transfer cable To transfer screen data to GP 4501T TW u...

Страница 19: ...re If you use the existing connection cables see 4 5 Cable Diagram at the time of replacement 2 6 2 Auxiliary I O Interface AUX for GP 3500S L only GP 4501T TW is not equipped with Auxiliary I O Featu...

Страница 20: ...cally change to the one that uses a SD card To change the setting of the output destination folder see 5 1 Changing the setting of the external media to use 2 7 Peripheral units and option units 2 7 1...

Страница 21: ...FG location is different GP 4501TW has a DC power supply type only When replacing GP ST 3500 series AC type with GP 4501TW changing to DC power supply is required 2 9 Backup Battery Unlike GP ST 3500...

Страница 22: ...r AC100V 108VA or lower AC240V 45W or lower GP 4501T 44VA or lower AC100V 58VA or lower AC240V GP 4501TW 17W or lower For the detailed electric specifications see the hardware manual 2 10 Materials Co...

Страница 23: ...eck the performance and start operation Change the received data on GP Pro EX Check and modify the data on GP Pro EX Transfer the screen data to GP 4501T TW Check the connection between GP 4501T TW an...

Страница 24: ...e available A USB transfer cable model CA3 USBCB 01 A USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B Possible to send receive a screen via a SD card except GP 4501TW...

Страница 25: ...model CA3 USBCB 01 A CF card USB storage device Ethernet But this section explains as an example how to receive screen data from GP ST 3500 series using a USB transfer cable model CA3 USBCB 01 If you...

Страница 26: ...depending on the security level of Windows XP Click Continue Anyway to start installing the driver When installation is completed click Finish If the following symptoms appear on Microsoft Windows 7...

Страница 27: ...o EX 3 Make sure that the Device in the Transfer Settings Information is set to USB If not click the Transfer Setting button to open the Transfer Setting dialog box Select USB in the Communication Por...

Страница 28: ...eceive Project and the following dialog box will appear Specify a place to save the received data in and a project file name and then click Save to start transfer NOTE When a convert to file exists th...

Страница 29: ...data the following dialog box will appear during transfer Specify a place to save the CF card data in Click OK and the Receive Project dialog box will return and transfer will be completed GP 4501T TW...

Страница 30: ...sfer Tool 3 4 Change the Display Unit Type Open the received project file prx of GP ST 3500 series on GP Pro EX and change the display unit type to GP 4501T TW 1 Open the received project file prx on...

Страница 31: ...u can transfer data to GP 4501T TW via A USB transfer cable model CA3 USBCB 01 A USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B A SD card A USB storage device Ethern...

Страница 32: ...ng on the security level of Windows XP Click Continue Anyway to start installing the driver When installation is completed click Finish If the following symptoms appear on Microsoft Windows 7 go to up...

Страница 33: ...he display unit After transferring a project file once this screen will not appear again 3 On the GP Pro EX s State Toolbar click the Transfer Project icon to open the Transfer Tool To transfer a diff...

Страница 34: ...gs field and click OK 5 Click Send Project to start transfer When the following dialog box appears click Yes This dialog box doesn t appear when the same project file is sent again 6 The following dia...

Страница 35: ...t file will be displayed 8 Close the Transfer Tool 9 Click the X mark on top right of the screen or Project Exit to close GP Pro EX 3 6 Differences of software Some functions supported by GP ST 3500 s...

Страница 36: ...unication with Device PLC 4 1 Driver list More connectable drivers will be added For the devices PLC each driver supports see Connectable Devices http www pro face com product soft gpproex driver driv...

Страница 37: ...COM2 NOTE If you use the connecting cable that was used for GP ST 3500 series see 4 5 Cable Diagram at the time of replacement When the both COM1 and COM2 ports on GP 3500S L have RS 422 485 setting d...

Страница 38: ...ignals of COM1 For GP 3500S L RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or...

Страница 39: ...or ST 3501T C RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown 39 49...

Страница 40: ...or GP 4501T TW RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown 40 4...

Страница 41: ...4 3 2 Signals of COM2 For GP 3500S L RS 422 485 socket For ST 3501T C RS 422 485 plug 41 49...

Страница 42: ...lug 4 4 Multilink Connection For the communication drivers that support serial multi link see Which drivers support serial multilink communication http www pro face com otasuke files manual gpproex ne...

Страница 43: ...is connected via the COM1 port if GP 3500S L is replaced with GP 4501T TW it will be connected via the COM2 port of GP 4501T TW The cable diagram can be still used Before GP 4501T TW is connected be...

Страница 44: ...rt Conversion Adapter CA3 ADPCOM 01 added IMPORTANT The user created cable for connection to GP 3500S via COM2 can t be used for GP 4501T TW When an option cable manufactured by Digital is used A cabl...

Страница 45: ...s replaced with GP 4501T TW only the COM2 port can be used on GP 4501T TW for RS 422 485 connection Using a USB RS 422 485 Conversion Adapter PFXZCBCBCVUSR41 allows you to use GP 4501T TW USB interfac...

Страница 46: ...USR41 with a Display unit the external devices you can connect to its serial interface RS 422 485 are limited For more information please refer to GP Pro EX Device PLC Connection Manual http www pro f...

Страница 47: ...ng 1 After conversion of the project file data at GP Pro EX Error Check if the message The project contains features that require a SD card However the selected display does not support SD cards so th...

Страница 48: ...tion Destination Folder ii Uncheck Enable SD Card and check Enable USB Storage iii Click the Browse button and specify a destination folder iv Click OK to confirm the setting v Click Project Save to s...

Страница 49: ...erence Manual 2 Check and change the destination folder setting following the steps below i Click Project Information Destination Folder ii The current setting is displayed iii After changing it click...

Отзывы: