Wiring the Floodlight

• 

Ensure that the mains supply is isolated before commencing installation.

• 

A suitable rated connector must be used to connect the lead from the floodlight to 

the mains supply.

• 

Connect the mains cable to the connector. Ensure that the correct polarities for 

Live, Neutral and Earth are observed i.e.

 

 

- Green/yellow - Earth terminal

 

- Brown - Live terminal

 

- Blue - Neutral terminal

 

 

After wiring, check that there are no stray strands and that all the wires have been 

correctly installed.

• 

Before connecting power, perform the electrical tests specified in the current 

Building and IET Wiring Regulation to ensure that the installation is safe and that 

the wiring has been performed correctly.

• 

Restore the mains power supply and check that the floodlight illuminates the 

required area. Tighten the floodlight using the bolts on the brackets.

CLEANING & MAINTENANCE

• 

Clean the floodlight only with a soft dry cloth. Do not use any chemicals, abrasives 

or solvents that could damage the floodlight.

• 

The floodlight has a sealed LED lamp and is maintenance free. The LED lamp 

cannot be replaced. When the LED lamp reaches the end of its life, the floodlight 

will have to be replaced.

OPERATION

Time

Sens

Lux

•  Adjusting the PIR Sensor

• 

There are three adjustments on the back of the PIR sensor, one adjusts the 

duration the floodlight remain lit, the second one is for the sensitivity of movement 

detection and the third is to set the level of ambient light before the sensor triggers 

the illumination. Some trial and error may be required to set these correctly.

• 

Adjust the light level so the floodlight doesn’t activate until the light level is low 

enough for floodlighting to be required.

• 

Adjust the timer setting for the required duration you require for the floodlight to 

remain illuminated.

Содержание PELL0289

Страница 1: ...conductors of at least 1 0mm cross sectional area must be used This product must be connected to Earth The front of this floodlight is made of tempered glass replace if cracked LED lamps are extremely bright To avoid possible damage to the eyes do not stare into an LED beam In use avoid touching any external surface of the floodlight due to the possibility of high temperatures Do not use near flam...

Страница 2: ... fixing holes Drill the fixing holes and fix the floodlight into position using appropriate size screws and wall plugs not provided Check that it is securely fixed This floodlight is suitable for outdoor lighting applications for domestic use only Do not use in areas where an explosive or chemical atmosphere may exist Do not use in areas where ventilation is restricted It is suitable for mounting ...

Страница 3: ...ighten the floodlight using the bolts on the brackets CLEANING MAINTENANCE Clean the floodlight only with a soft dry cloth Do not use any chemicals abrasives or solvents that could damage the floodlight The floodlight has a sealed LED lamp and is maintenance free The LED lamp cannot be replaced When the LED lamp reaches the end of its life the floodlight will have to be replaced OPERATION Time Sen...

Страница 4: ...0kg Dimensions WxHxD mm 174x115x60 INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local...