Seasonal Cleaning
If the air conditioner is not going to be used for a long time, please follow the steps
below:
•
Unplug the air conditioner from the mains.
•
Remove the drainage plug and empty the internal water tank.
•
Plug the air conditioner into the mains and power on. Select the fan mode and run
for two hours to allow the air conditioner to dry out.
•
Turn off and unplug from the mains.
•
Clean and dry the filters and then reinstall them.
•
Remove the batteries from the remote control.
•
Put the air conditioner back in its original carton and store in a cool, dry place.
•
Long term storage
•
Unscrew the drainage cover, unplug the water plug, and discharge the water in the
water pan into other water containers or directly tilt the body to discharge the water
into other containers.
•
Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state
until the drainage pipe is fully dry, so as to keep the inside of the body in a dry
state and prevent mildew.
•
Turn off the machine, unplug the mains plug, and wrap the power cord around the
cable storage and install the drain plug and the drainage cover.
•
Remove the exhaust pipe and keep it safely.
•
Cover the appliance with a plastic bag. Store in a dry place, keep it out of the
reach of children, and take dust control measures.
•
Remove the batteries from the remote control.
FURTHER SAFETY INFORMATION
Information on servicing
•
Checks to the work area prior to beginning work on systems containing flammable
refrigerants, safety checks are necessary to ensure that the risk of ignition is
minimised. For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
Work procedure
•
Work shall be undertaken under a controlled procedure so as to minimise the risk
of a flammable gas or vapour being present while the work is being performed.
General work area
•
All maintenance staff and others working in the local area shall be instructed on
the nature of work being carried out. Work in confined spaces shall be avoided.
The area around the workspace shall be sectioned off. Ensure that the conditions
within the area have been made safe by control of flammable material.
Checking for presence of refrigerant
•
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e. non-sparking, adequately sealed or
intrinsically safe.