Before connecting the power, perform the electrical tests specified in the current
Building and IET Wiring Regulations to ensure that the installation is safe and that
the wiring has been performed correctly.
•
Switch on the electricity to check that the floodlight illuminates. Adjust the angle of
the floodlight so that it illuminates the required area. Tighten the floodlight using
the bolts on the brackets.
REMOTE CONTROL
•
The distance between two luminaires should be more than 50cm, with no large
metal obstructions in front of the luminaires.
•
The default settings:
> Sensitivity: 100%
> Duration time: 10s
> Mode: Daylight
Mode
Daylight mode (sensor works both in
the day and at night)
Nigh
t
light mode (sensor works only
at night, < 50 lux)
Photocell mode (the floodlight lights
automatically at night, < 50 lux)
Not supported by this model
Manual override mode: keep light on
all of the time
Flash mode
SOS mode
Off mode
Sensitivity
100%
7~8m
75%
5~6m
50%
3~4m
25%
1~2m
Time
(Duration time from light on to off)
Minimum:
5 seconds
Maximum:
24 hours