background image

4

 Momentum mo8 Manual

1.   Read these instructions carefully.
2.   Retain these instructions for future reference.
3.   Heed all warnings.
4.   Follow all instructions.
5.   Do not use any part of this apparatus near water.
6.   Do not block any ventilation openings.
7.   Do not install near any heat source.
8.   Do not defeat the safety purposes of the polarized or grounding type plugs.
9.   Do not use the Momentum power supply for any purpose other than stated in this manual.
10.  Only use Pro Co recommended accessories with any Momentum device.

To reduce the risk of fi re or electrical shock, do not expose 

any part of your Momentum System to rain or moisture.

To reduce the risk of electrical shock, do not remove cover. There are no 

user serviceable parts inside. Refer servicing to service personnel.

Always follow the basic precautions listed below to avoid the possibility of physical injury to 

you or others, or damage to the device or other property. These precautions include, but are 

not limited to, the following:

Use Extreme Caution!

Before making adjustments to your Momentum system, be aware that certain actions could possibly 

damage your hearing and/or the audio system itself.  Think through your actions and the possible 

ramifi cations of your adjustments. Proceed with caution and follow these important Safety Instructions:

Safety Precautions

Содержание Momentum MO8

Страница 1: ...Eight Channel Analog Output Manual mo8 Pro Co Sound Inc 225 Parsons Street Kalamazoo MI 49007 1 888 253 7360 www procomomentum com...

Страница 2: ...tive or dealer must perform all warranty servicing of the units otherwise all aspects of this warranty are void 2 All tamper proof seals on the unit s must be intact in order for the unit s to be serv...

Страница 3: ...tion and Startup Power Network Wiring Copper Wiring Copper Connection Fiber Connection Network Configuration Setup Network Clock Sync Using the Control Panel Setting Device Start Channel IP Address Sa...

Страница 4: ...hock do not expose any part of your Momentum System to rain or moisture To reduce the risk of electrical shock do not remove cover There are no user serviceable parts inside Refer servicing to service...

Страница 5: ...in the successes and failures of our efforts Welcome to the Pro Co Family Upon receiving your Momentum System please check all cartons for damage If there is damage notify the shipper and dealer in t...

Страница 6: ...the inherent problems that are associated with traditional wiring Flexibility and expandability are enhanced through the use of modules for inputs outputs and DSPs Signal routing becomes as easy as cl...

Страница 7: ...nel XLR connectors This also allows passive splitting of the analog signals if needed Pro Co offers whatever breakout cables you need Just ask for them when you order your system mo8 Front View with o...

Страница 8: ...Active Link Shows network activity 2 TX Indicates that the mo8 is transmitting data on the network 3 1000m Indicates that the mo8 is connected at one gigabit 4 Quality Indicates an acceptable Etherne...

Страница 9: ...is power supply comes with three jumper cables that will allow up to four units to be linked together and powered by one MUPS The MUPS is an additional option and must be ordered separately Use a stan...

Страница 10: ...opper Connection Use T568B or equivalent connectors when wiring your system This view shows the color code as viewed from the front of the female socket or the rear of the male connector Crossover wir...

Страница 11: ...re endless For more information on advanced configurations and support visit www procomomentum com For further support con tact you local dealer or Pro Co technical support One to One Connection CAT5E...

Страница 12: ...007 mo8 Output mo8 Output mo8 Output mo8 Output FOH CAT5E or CAT6 Optional Fiber Note Running both Fiber and CAT6 copper or two CAT6 copper connections can provide a redundant link between FOH and th...

Страница 13: ...trol PC to multicast filtering Multicast MAC 01 15 AB C6 00 00 See Network Design White Papers mo8 Output Chn 001 mo8 Output Chn 009 Chn 017 Chn 025 Chn 033 Chn 041 mo8 Output mo8 Output mo8 Output mo...

Страница 14: ...etwork Using the Control Panel F1 Mode Edit Decrease Value F2 Mode Select Increase Value Display Status Indicator Power Indicator Button LED Description F1 Mode Select F1 activates the edit mode withi...

Страница 15: ...68 1 1 When in the idle menu state pressing the F1 button will flash the current ad dress The number shown is the LSB of the IP address 192 168 1 LSB If the network is to be controlled with a PC each...

Страница 16: ...ey strokes between F1 and F2 In general F2 selects which function to edit and F1 activates the edit mode within that function The flow chart below displays each of the controlling F1 and F2 functions...

Страница 17: ...press F1 F2 to exit or allow display to time out 6 To return to the beginning of the menu allow the display to time out When the display times out and when the unit is at idle the start channel numbe...

Страница 18: ...3 Tap F1 to decrease value Press F2 in increase value Toggle F2 to select Clr to set the IP 4 to factory default of 192 168 1 1 Press and hold F1 and F2 to execute and save the change 5 Exit by allow...

Страница 19: ...uency Response 20 20kHz 0 05dB Network Specifications Standard Gigabit Ethernet Protocol Power Over Ethernet PoE 802 3af Compliant Up to 256 total active system inputs at 48K or 96K sampling Onboard m...

Отзывы: