6
CHARGING INDICATIONS
When your battery charging system is activated, the battery status indicators provides charging information utilizing five red
LED indicators and one green LED indicator.
There are two sets of status LED
’s, one for each DC output.
Your Dual Power Series charging system is factory set to the DeltaVolt
selection, this allows both DC outputs to run flooded lead acid charging
profiles.
Additionally, each DC output may be configured, utilizing the DeltaView Link
App (available free for Android and iOS), to run AGM or Lithium charging
profiles. Further information is available at
Two amber LED indicators per battery system are provided in order to display what type of battery the charger has been
programmed to charge.
NOTE:
For information on reconfiguring the battery type, please contact technical support
(800.742.2740).
Battery System Percent Charged Indicators
Four LED indicators are provided in order to display the progress of the charge cycle in percentage of charge.
Indications are as follows:
1
ST
Amber LED . . . . . . . . . . . . . . . . . . Illuminated configured for Flooded Lead Acid
2
ND
Amber LED . . . . . . . . . . . . . . . . . . Illuminated configured for either AGM or Lithium
– see real time app display
1
ST
RED blinking. . . .
……. …………….Charger plugged into A/C not connected to battery
1
ST
RED LED . . . . . . . . . . . . . . . . . . . Charging - Initial Charging Up To 30%
2
ND
& 3
RD
RED LEDS . . . . . . . . . . . . Charging - 60% Complete
1
ST
, 2
ND
& 3
RD
RED LEDS. . . . . . . . .
Charging - 90% Complete
BLINKING GREEN LED . . . . . . . . . . Finishing Stage (Note: Battery Type Indicator will also blink during this stage)
STEADY GREEN LED . . . . . . . . . . . . Charge Complete
–Float/Maintenance Mode-On for 5 minutes and off for 60 minutes
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle. After the completion of
the charge cycle, the green LED will remain on steady during the float-maintenance stage.
During this final stage current
is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.
Your system provides an equalization stage every 30 days while plugged in. If the charger is normally disconnected
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce
sulfation on the lead plates of a battery, which helps promote longer battery life. Note: During this process the
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated Red
LED Battery Type) and then the Green LED and Red Battery Type LED will blink) until the unit returns to the
maintenance mode and a steady Green LED and steady Red Battery Type LED. (Not applicable to Gel Profile)