Pro Charging Systems DP24/12 Скачать руководство пользователя страница 6

 

 
 
CHARGING INDICATIONS 

When your battery charging system is activated, the battery status indicators provides charging information utilizing five red 
LED indicators and one green LED indicator. 

 

 

 
 
 
There are two sets of status LED

’s, one for each DC output. 

 
Your Dual Power Series charging system is factory set to the DeltaVolt 
selection, this allows both DC outputs to run flooded lead acid charging 
profiles. 
 
Additionally, each DC output may be configured, utilizing the DeltaView Link 
App (available free for Android and iOS), to run AGM or Lithium charging 
profiles.  Further information is available at 

www.dualpro.com

. 

 
 
 
 

 

Two amber LED indicators per battery system are provided in order to display what type of battery the charger has been 
programmed to charge.  

NOTE:

 For information on reconfiguring the battery type, please contact technical support 

(800.742.2740). 

 
Battery System Percent Charged Indicators  

Four LED indicators are provided in order to display the progress of the charge cycle in percentage of charge.   
Indications are as follows: 
 
1

ST

 Amber LED . . . .  . . . . . . . . . . . . . .  Illuminated configured for Flooded Lead Acid 

2

ND

 Amber LED . . . . . . . . . . . . . . . . . .  Illuminated configured for either AGM or Lithium 

– see real time app display 

1

ST 

 RED  blinking. . . . 

……. …………….Charger plugged into A/C not connected to battery

 

 

1

ST 

 RED LED . . . . . . . . . . . . . . . . . . .   Charging - Initial Charging Up To 30% 

2

ND

 & 3

RD

 RED LEDS  . . . . . . . . . . . .    Charging - 60% Complete  

1

ST

, 2

ND

 & 3

RD

 RED LEDS. . . . . . . . .   

Charging - 90% Complete  

BLINKING GREEN LED  . . . .  . . . . . .  Finishing Stage (Note: Battery Type Indicator will also blink during this stage)  
STEADY GREEN LED  . . . . . . . . . . . .  Charge Complete 

–Float/Maintenance Mode-On for 5 minutes and off for 60 minutes 

 
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the 
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle.  After the completion of 
the charge cycle, the green LED will remain on steady during the float-maintenance stage.  

During this final stage current 

is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.   
 

Your system provides an equalization stage every 30 days while plugged in.  If the charger is normally disconnected 
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage 
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce 
sulfation on the lead plates of a battery, which helps promote longer battery life.  Note:  During this process the 
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated  Red 
LED Battery Type) and then the Green LED and Red Battery Type LED will blink) until the unit returns to the 
maintenance mode and a steady Green LED and steady Red Battery Type LED. (Not applicable to Gel Profile) 

 
 
 
 
 
 
 

Содержание DP24/12

Страница 1: ...ls DP24 12 DP36 12 _______________________________________ 030920 70348 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC powe...

Страница 2: ...efinitions This symbol means Immediate hazards which will result in severe personal injury or death This symbol means Hazards or unsafe practices which could result in severe personal injury or death...

Страница 3: ...ay have it repaired by an authorized technician Do not disassemble charger contact PCS technical support when service or repair is required 800 742 2740 Incorrect reassembly may result in risk of elec...

Страница 4: ...nsion cord before use for damage bent prongs and cuts Replace if damaged Connect the extension cord to the charger then proceed to plug the extension cord to the GFCI protected Ground Fault Circuit In...

Страница 5: ...erie et les taux de chargement recommand s Never place the charger directly above or below the battery being charged gases or fluids from the battery will corrode and damage the charger Locate the cha...

Страница 6: ...D RED LEDS Charging 60 Complete 1ST 2ND 3RD RED LEDS Charging 90 Complete BLINKING GREEN LED Finishing Stage Note Battery Type Indicator will also blink during this stage STEADY GREEN LED Charge Compl...

Страница 7: ...for proper polarity black wire to negative or Also check for corrosion free secure connections to the battery 30 60 RED LEDS BLINKING FORMING STAGE TIMEOUT SHUTDOWN This indication occurs if the batte...

Страница 8: ...cally have a warranty start date that will be the two year anniversary of the production date This limited warranty is void if the product is misused improperly maintained handled carelessly or incorr...