PRO Charging System i1215BSBDUAL Скачать руководство пользователя страница 4

NEVER charge a frozen battery. 
 

PREPARING TO CHARGE 

If it is necessary to remove the battery or batteries to charge, always remove grounded terminal from 
battery first.  Make sure all accessories are off, so as not to cause battery arcing. 
 
Be sure the area around any battery is well ventilated while batteries are being charged.  On occasion, 
“gas fumes” may be present during charging and can be forcefully blown away by using a piece of 
cardboard or other nonmetallic material as a fan.  Proper ventilation is always recommended in the 
charging area. 
 
Clean all of the battery terminals.  Be careful to keep corrosion from coming into contact with eyes. 
 
Add distilled water in each cell (wet cell batteries) until battery acid reaches level specified by battery 
manufacturer.  This helps purge excessive gas from cells.  Do not overfill.  For a battery without cell caps, 
carefully follow manufacturer’s recharging instructions. 
 
Study all battery manufacturers’ specific precautions such as removing or not removing cell caps while 
charging and recommended rates of charge. 
 
Extension cords should be industrial grade/heavy duty UL approved and grounded.  Check extension 
cord before use for damage, bent prongs and cuts.  Replace if damaged. 
 
Always make your extension cord connection on the charger side first.  After connecting the extension 
cord to the charger, proceed to plug the extension cord into a 120VAC GFCI protected (Ground Fault 
Circuit Interrupt) outlet.  
 
Always remove the extension cord from the 120VAC outlet first when charging is completed followed by 
unplugging the charger. 
 

PRODUCT SUMMARY 

General Operation: 

Use the following guidelines in this manual to install your fully automatic PCS battery charging system.   
 
Assure that the area around your charger and batteries is properly ventilated.  Connect your extension 
cord with no AC power present to the battery charger and proceed to plug your extension cord in at a 
nearby 120VAC outlet. 
 
Once you plug in your PCS battery charging system, your batteries will be simultaneously and 
independently charged to 100%.  Unlike systems that utilize one large charger to attempt to charge 
multiple batteries, your system utilizes a totally independent battery charger for each battery.  Each 
charging bank will remain in a maintenance (“float”) stage once the battery is charged and then monitor 
and/or maintain the battery indefinitely provided that you leave your system plugged in, which is what we 
recommend.  

During the Float stage current will flow to the battery for 5 minutes and then shut off 

completely for 60 minutes. 
 
Your system provides an equalization stage every 30 days while plugged in.  If the charger is 
normally disconnected from A/C after completing charge, equalization can be accomplished by 
plugging back into A/C whenever this stage is desired. Battery manufacturers recommend that 
equalization is done once a month in order to further reduce sulfation on the lead plates of a 
battery, which helps promote longer battery life.  Note:  During this process the LEDs will go 
through their normal routine(Red counting up for % of charge) and the Green Led will blink until 
the unit returns to the maintenance mode and a steady Green LED.  (Not applicable to a Gel Profile) 

 

INDEPENDENT CHARGING BANK INDICATIONS 

When your battery charging system is activated, each bank provides charging information utilizing five red 
Light Emitting Diode (LED) indicators and one green Light Emitting Diode (LED) indicator. 
 

 

Содержание i1215BSBDUAL

Страница 1: ..._______________________________________ 070914 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Systems PCS charger Contact technical support at PCS with any product installation or service questions 800 742 2740 Pro Charging Systems LLC LaVergne TN 37086 3539 ...

Страница 2: ... and installation instructions before installing or applying AC power to your on board battery charging system Please contact us with any product installation or service questions at technical support 800 742 2740 INTRODUCTION Pro Charging Systems LLC PCS has been manufacturing high quality high performance charging systems since 1989 Our charging systems are designed and built tough to withstand ...

Страница 3: ...f battery Review all cautionary markings on any product being utilized in or around the charging device PERSONAL PRECAUTIONS Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing eyes or other surfaces Wear complete eye protection and clothing pro...

Страница 4: ... guidelines in this manual to install your fully automatic PCS battery charging system Assure that the area around your charger and batteries is properly ventilated Connect your extension cord with no AC power present to the battery charger and proceed to plug your extension cord in at a nearby 120VAC outlet Once you plug in your PCS battery charging system your batteries will be simultaneously an...

Страница 5: ... compartment wall is chosen make certain its strength is adequate to support the weight of the charger Use the mounting flanges of the charger to mark locations for starter holes Drill a 1 16 inch hole at each marked location Then utilize all stainless steel screws that have been provided and install the charger securely being cautious not to over tighten the screws Silicon sealer should be used t...

Страница 6: ...should now observe a red LED indication on each bank of the charger representing each individual battery being charged The voltage of each battery will reflect the number of LED indicators illuminated When charging is complete remove the extension cord from the 120VAC outlet first and then unplug the charger TROUBLE SHOOTING PROBLEM No LED indicators illuminate in any of the charger banks Solution...

Страница 7: ...ntal applications and Heavy Industrial applications Sometimes RM is designated in the PCS Part number when ordered but is not part of the model number Chargers used in Restricted Markets will have a warranty period of 18 months from the date of retail purchase against defective materials and or workmanship CR refers to Certified Reconditioned and designates a 1 year warranty If such defects should...

Страница 8: ...Below are some of our other options in chargers and battery accessories Call our technical support group for more detailed information or visit our web site www pcsdv com www pcsdv com 8 ...

Отзывы: