6276XY
(addr 1, see documentation for key layout)
6276XY
(addr 2, see documentation for key layout)
6276XY-MON
(addr 3, 6276XY—Mon (Sirius)
6277-8
(addr 4, all sources, dest 1-8, 65-72)
6277-8
(addr 5, all sources, dest 9-16, 73-80)
6277-8
(addr 6, all sources, dest 17-24, 81-88)
6277-8
(addr 7, all sources, dest 25-32, 89-96)
6277-8
(addr 8, all sources, dest 33-40, 97-104)
6277-8
(addr 9, all sources, dest 41-48, 105-112)
6277-8
(addr 10, all sources, dest 49-56, 113-120)
6277-8
(addr 11, all sources, dest 57-64, 121-128)
6705 BPX
(addr 12, sources 1-32, dest 1)
6705 BPX
(addr 13, sources 33-64, dest 1)
6705 BPX
(addr 14, sources 65-96, dest 1)
6705 BPX
(addr 15, 6706, sources 97-128, dest 1)
6705 SplitXY
(addr 16, 6706, sources 1-16, dest 1-16)
RS485-2
Panel Settings
6276XY and 6277-8 Panel Switch settings at rear
UP
1
UP
2
UP
3
DWN
4
DWN
5
UP = 6277
DWN = 6276
6
DWN
7
UP
8
6705 BPX - sw 7 ON, all others OFF
6705 SplitXY - sw 6 & sw 7 ON, all others OFF
Note: The RS485 cable is wired pin to pin. Ensure the multi-drop address is set correctly for each panel.
If using a configured database the Nebula Editor will show this as CURR_SYS, and the panels may be
configured as required. SW7 = ON. Refer to the handbook for editing details.
RS485-1
Sirius Router Fixed Database Panel Configuration.
For RS485-2 panel details, see documentation.
Fixed Database Control Sub-Board Switch Settings
Use the following settings when connecting control panels directly to ports RS485-1 and 2.
Master 2434 switch settings shown in bold. For slave control card, SW1 is OFF.
ON
sw
OFF
Mstr
1
Slve
20MHz
2
10MHz
3
OFF
38400
4
9600
525
5
625
Auto
6
manual
Config
7
fxd
Panels
8
genrl