background image

 

 

 

6276XY 

(addr 1, see documentation for key layout)  

6276XY 

(addr 2, see documentation for key layout)  

 

6276XY-MON 

(addr 3, 6276XY—Mon (Sirius)  

 

6277-8 

(addr 4, all sources, dest 1-8, 65-72) 

 

6277-8 

(addr 5, all sources, dest 9-16, 73-80) 

 

6277-8 

(addr 6, all sources, dest 17-24, 81-88) 

 

6277-8 

(addr 7, all sources, dest 25-32, 89-96) 

 

6277-8 

(addr 8, all sources, dest 33-40, 97-104) 

 

6277-8 

(addr 9, all sources, dest 41-48, 105-112) 

 

6277-8 

(addr 10, all sources, dest 49-56, 113-120) 

 

6277-8 

(addr 11, all sources, dest 57-64, 121-128) 

 

6705 BPX 

(addr 12, sources 1-32, dest 1) 

 

6705 BPX 

(addr 13, sources 33-64, dest 1) 

 

6705 BPX 

(addr 14, sources 65-96, dest 1) 

 

6705 BPX 

(addr 15, 6706, sources 97-128, dest 1) 

 

6705 SplitXY 

(addr 16, 6706, sources 1-16, dest 1-16) 

RS485-2 

 
Panel Settings 
 
6276XY and 6277-8 Panel Switch settings at rear 

UP 

UP 

UP 

DWN 

DWN 

UP = 6277 

DWN = 6276 

DWN 

UP 

 

 

6705 BPX - sw 7 ON, all others OFF 

 

6705 SplitXY - sw 6 & sw 7 ON, all others OFF 
Note:  The RS485 cable is wired pin to pin.  Ensure the multi-drop address is set correctly for each panel. 

If using a configured database the Nebula Editor will show this as CURR_SYS, and the panels may be  
configured as required.  SW7 = ON.  Refer to the handbook for editing details.  

RS485-1 

Sirius Router Fixed Database Panel Configuration.        

For RS485-2 panel details, see documentation.

 

Fixed Database Control Sub-Board Switch Settings

 

 

Use the following settings when connecting control panels directly to ports RS485-1 and 2. 
 
Master 2434 switch settings shown in bold.  For slave control card, SW1 is OFF. 

ON 

sw 

OFF 

Mstr 

1 

Slve 

20MHz 

10MHz 

 

OFF 

38400 

9600 

525 

625 

Auto 

manual 

Config 

fxd 

Panels 

genrl 

Отзывы: