Specification

Inputs

Number and type:

One serial digital video input to EBU Tech 3267E,
SMPTE 259M - ABCD or ASI (EN 50083-9)

Impedance:

75

 unbalanced

Data rate:

3 Mbit/s to 400 Mbit/s (continuous)

Outputs

Number and type:

Ten as input, equalised, only 5 available with 20mm
BNC rear panel

Compatibility:

All outputs are compatible with SDI/SDTI. Only the
first five are non-inverting and can be used with ASI
format signals

Impedance:

75

 unbalanced

Performance

Input return loss:

> 15dB to 300MHz, > 12.5dB to 400MHz 

Max output level:

800mV into 75

W

  load

Output return loss:

> 15dB to 300MHz, > 12.5dB to 400MHz 

Output rise time:

<500ps

Overshoot:

<5%

Cable equalisation:

> 250 metres of Belden 8281 or PSF1/2, (300 metres 
typical) at 270Mbit/s
> 200 metres of PSF1/3, (250 metres typical) at
270Mbit/s

LED indicators

Power OK - green

Rear panels

K3404-2, five output 20mm wide rear connector
K3404-3, ten output 30mm wide rear connector
K3404-2M, ten output SMB, 20mm wide rear
connector

6

 

Issue 2

3404

Содержание ICO-3404-2000

Страница 1: ...duction 2 2 Configuration and operation 3 2 1 Selecting the rear connector 3 2 2 Trouble shooting 4 3 Status monitoring 5 4 Specification 6 5 Ordering information 7 Technical Manual 1 Digital Video No...

Страница 2: ...DTI ASI and MADI The features available are five outputs with the 20mm K3404 2 rear connector ten outputs with the 30mm K3404 3 rear connector ten outputs with the 20mm K3400 2M five outputs are DVB A...

Страница 3: ...is the K3400 2M This has a BNC input and 10 SMB outputs and is only 20mm wide This is supplied with ten 1 6m long SMB BNC cables for easy interconnection to other equipment with BNC connections Please...

Страница 4: ...nals The Power LED is not lit check mains power to the frame is turned on if necessary check the PSU as explained in the power supply section check the card is plugged in securely check to see if the...

Страница 5: ...to the COSMOS status monitoring controller if fitted module present module type module bar code module issue no For further details of the Pro Bel status monitoring system please refer to the COSMOS s...

Страница 6: ...n be used with ASI format signals Impedance 75W unbalanced Performance Input return loss 15dB to 300MHz 12 5dB to 400MHz Max output level 800mV into 75W load Output return loss 15dB to 300MHz 12 5dB t...

Страница 7: ...art number Description ICO 3404 2000 5 output non reclocking SDI ASI DA 20mm ICO 3404 3000 10 output non reclocking SDI DA 30mm ICO 3404 2M00 10 output SMB non reclocking SDI DA 20mm Issue 2 7 Digital...

Отзывы: