background image

 

 

 

 

 

 

Page

 7 

 

 

 

 

2.6

 

Repair and Calibration service 

We are always at your disposal with our service support. For any malfunctioning, you 
can  simply  send  the  product  back  to  us  with  a  short  description  of  the  problems 
observed.  Please  don’t  forget  to  mention  your  telephone  number  so  that  we  can 
contact you for any possible queries.  

We  shall  inform  you  about  the  likely  amount  of  repair  charges  before  taking  up  the 
repair  activity.  The  cost  estimate  is  provided  free.  The  postage  and  packing  charges 
for return are to be added over and above the repair costs. 

In  our  calibration  laboratory,  we  can  also  calibrate  your  measurement  and  test 
equipment of other  makes with repeatability of National standards.  Please send your 
enquiries to us; we shall prepare an offer for you without any order commitment! 

 

Service address: 

Pro air GmbH 
- calibration service - 
Peter-Müller Strasse 29a 
80997 München, Germany 

Telefon  0049 - 89 / 81888-234 
Telefax  0049 - 89 / 81888-236 

Email 

[email protected] 

Internet 

www.pro-air.eu

 

 

 

 

 

 

The technical information in this document has been checked with adequate care at our end and in intended 
to inform about the product and its applications. The descriptions are not to be understood as assurance of 
the defined characteristics of the  product and should  be checked  by the user for the intended application. 
Any possible industrial third party patent rights are to be considered.    

 

Issued July 2005 - This documentation supersedes all previous editions. 

 

© Copyright 2004 Pro air GmbH. All rights reserved. 

No  part  of  this  documentation  is  allowed  to  be  stored,  reproduced,  processed,  duplicated  or  published  in 
any form without prior written permission from the company Pro air GmbH.

 

Содержание TPW Portable

Страница 1: ...escription of the Handy measuring instrument TPW portable Picture of the instrument Connections of the instrument The hygro thermometer TPW portable is provided with various connection points on the t...

Страница 2: ...t for the first time please open the battery compartment with a screw driver and put batteries in it Connect the sensor connection cable of the measuring probe at the corresponding socket on the front...

Страница 3: ...f the buttons The buttons perform the following basic functions Name Function Switching ON OFF the instrument Hold value in the display Toggle between C and F Display Dew point and Absolute humidity D...

Страница 4: ...sign appears in the display MIN MAX button is pressed again Maximum of measured values is displayed MAX sign appears in the display On request The Dew point or Absolute humidity value can be shown on...

Страница 5: ...Operation of button Action Display contents The instrument is in normal operation td aH button is pressed Dew point is displayed td sign appears in the display td aH button is pressed again Absolute...

Страница 6: ...pressed Temperature scale changed to F In display the measured value is shown in F HYGROSENS RH F C F button is pressed Temperature scale is changed back to C In display the measured value is shown i...

Страница 7: ...is in normal operation HOLD button is pressed Display of current measured value is fixed HOLD sign appears in the display HYGROSENS RH C HOLD On request The finally measured Dew point or the finally m...

Страница 8: ...prepare an offer for you without any order commitment Service address Pro air GmbH calibration service Peter M ller Strasse 29a 80997 M nchen Germany Telefon 0049 89 81888 234 Telefax 0049 89 81888 2...

Отзывы: