3
prismatibro.se | Prisma Light
Mounting ground plate
1. Remove the opening cover.
2. Screw the tube to ground
and press the rubber collar
to the ground.
3. Connect the ground
cables (230V) to the fuse.
4. Attach the lamp head to
the pipe, tool T-30H
max 5 Nm
5. Connect the lamp head
contact to the fuse.
6. Attach the opening cover
Mounting foundation
1. Remove the opening cover.
2. Place the tube into the
foundation, hammer down
the locking wedge and push
the rubber collar to the
ground.
3. Connect the ground
cables (230V) to the fuse.
4. Attach the lamp head to the
pipe, tool T-30H max 5 Nm
5. Connect the lamp head
contact the fuse.
6. Attach the opening cover
Tool
Tamper-resistant Torx T-30H
INSTALLATION
Installation
Note the round label on the top.
Prisma Light Ella should be turned so that the
label is pointing out towards the road for the
light distribution to be right. See the direction of the arrow.
This label should be removed after installation.
Pri
s
ma
Lig
h
t
Ell
a
s
ee
n
f
r
o
m
a
bove
Only 230 V
Connection voltage
230V AC, 50Hz.
Connection power
20W
The luminaire is connected to wiring inside the pipe.
Prisma Light Ella is equipped with a driver with a fixed setting.