Mounting ground plate

 

1.  Remove the opening cover.

2.  Screw the tube to ground

 

and press the rubber collar 

 

to the ground.

3.  Connect the ground 

 

cables (230V) to the fuse.

4.  Attach the lamp head to 

 

the pipe, tool T-30H 

 

max 5 Nm

5.  Connect the lamp head 

 

contact to the fuse.

6.  Attach the opening cover

Mounting foundation

1.  Remove the opening cover.

2.  Place the tube into the 

 

foundation, hammer down 

 

the locking wedge and push 

 

the rubber collar to the 

 ground.

3.  Connect the ground 

 

cables (230V) to the fuse.

4.  Attach the lamp head to the 

 

pipe, tool T-30H max 5 Nm

5.  Connect the lamp head

 

contact the fuse.

6.  Attach the opening cover

Tool

 

Tamper-resistant Torx T-30H

INSTALLATION

Installation

Note the round label on the top.

Prisma Light Ella should be turned so that the 

label is pointing out towards the road for the 

light distribution to be right. See the direction of the arrow. 

This label should be removed after installation.

Pri

s

ma

 Lig

h

t

 Ell

s

ee

n

 

f

r

o

a

bove

Only 230 V

Connection voltage

 

230V AC, 50Hz.

Connection power

 20W

The luminaire is connected to wiring inside the pipe.

Prisma Light Ella is equipped with a driver with a fixed setting.