PILOT function box (modelling lamp) 

 

The modelling lamp is switched on or off using 

the “PILOT” buttons.  

MBX 500 is equipped with a LED array as modelling lamp; the light output is equivalent to 
that of an 80W halogen lamp. It always lights up with maximum power and is not dimmable. 
The mode FREE and PROP is not available. 

 

Bear in mind that longer operation of the modelling lamp consumes battery capacity 
which  is  then  no  longer  available  for  the  flash.  Therefore,  it  is  advised  to  limit  the 
operation time with the pilot light switched on.  

 
RADIO function box (radio operation) 

 

For remote radio operation, use the three radio buttons on the right. 

 

ON: 

If  the  ON  button  is  activated  (control  LED  lights  up),  the  flash  can  be  triggered  and 
controlled by radio. Additional entries for TEAM and ID are required. 

 

Team/ID: 

Selection  of  a  team  (A,  B,  or C)  or  an  ID  (1  to 9)  is done  by  pressing  the  Team or  the  ID 
button,  resp.,  and  simultaneously  turning  the  control  knob  until  the  desired  selection  is 
indicated  on  the  LED  display.  By  adjusting  all  possible  combinations,  a  maximum  of  27 
flash units (3x9) can be individually triggered and controlled. 

 

 

 

Team and ID can be changed only when the radio function is “ON”. 

 

 
AUXILIARIES function box (additional functions) 

 

Slave: 

If  the  “Slave”  button  is  activated,  an  external  flash  is  triggered  via  the  photocell  (see  the 
section entitled “Flash triggering” below). 

FC:  

IF  FC  (Flash  Check)  is  activated,  the  modelling  lamp  goes  off  immediately  after  the  flash 
has  been  released  and  lights  up  again  only  after  the  unit  has  charged  up  to  the  selected 
level. This ensures correct charging as well as renewed flash readiness. The flash control 
ensures that the flash lamps light up when several flash units are used. 

Audio: 

If 

the “Audio” button is activated, flash readiness is indicated by an acoustic signal. 

 

Test 

Test flashes can be released by 

pressing the “TEST” button.  

For additional flash triggering options, please refer to the next section. 

 

Flash readiness 

Flash  readiness  is  indicated  by  1.) 

lighting up of  the  “TEST”  button; 2.)  green  light of  the 

plastic  cap  covering  the  photocell;  3.)  re-lighting  up  of  the  modelling  lamp  when  FC  is 
activated; and 4.) an acoustic signal when the Audio function is switched on. 

 

Содержание MBX 500 HotSync

Страница 1: ...www priolite com Declaration of Conformity The company PRIOLITE GmbH Gattingerstr 7 D 97076 W rzburg Germany declares that the products MBX 500 HotSync are in conformity with the following standards...

Страница 2: ...PRIOLITE GmbH Gattingerstr 7 D 97076 W rzburg Tel 49 0 931 20700000 eMail info priolite com http www priolite com Instruction manual Instruction manual MBX 500 HotSync MBX 500 HotSync...

Страница 3: ...battery the power output ranges from 16J to a maximum of 500J covering 6 f stops precisely adjustable in 1 10 increments The flash recycle time to maximum output is around 2 8 seconds The modelling l...

Страница 4: ...nnector and replace it with a new one to be ordered from PRIOLITE by plugging the three contacts into the sockets Before using the unit once again the glass dome is to be mounted for safety reasons Re...

Страница 5: ...a flash from another unit strikes the first unit This operating mode is activated by pressing the Slave button control LED is on The photocell is designed as an impulse photocell Thus it works only w...

Страница 6: ...en on the unit only when it has been switched off and after the waiting period has expired Contact with the capacitor voltage is life threatening thus the opening of the casing and repairs on the comp...

Страница 7: ...uish the flames with water but use sand Damaged Lithium ion batteries are readily to be disposed of in appropriate containers Lithium ion batteries contain flammable and or corrosive solutions and Lit...

Страница 8: ...he desired selection is indicated on the LED display By adjusting all possible combinations a maximum of 27 flash units 3x9 can be individually triggered and controlled Team and ID can be changed only...

Страница 9: ...le connected to the mains outlet The charging unit is intended for global supply voltages multivoltage 230V 115V The charging time of a flat battery to full charge is approximately 3 hours Full charge...

Страница 10: ...full power 500 Ws 5 min power 16 Ws No of flashes charge 220 full power display 10 440 250 Ws display 9 more than 6000 at low power Charger 16V Multivoltage Charging time approx 2h to 80 and approx 3...

Страница 11: ...until the glass dome snaps audibly into the springs For dismounting hold the glass dome firmly with both hands Then tilt it slightly so that it disengages from the mounting springs and pull the glass...

Страница 12: ...tion in the room in which it is to be used This should prevent the formation of leakage current which can develop due to precipitation Overheating All units are equipped with a fan to prevent damage t...

Отзывы: