Priolite M-PACK 1000 (HS) Скачать руководство пользователя страница 10

Instruction manual  PRIOLITE M-PACK 500 / M-PACK 1000 (HS) + PRIO HEAD 1000 

PRIOLITE GmbH Wuerzburg - Last revised: 08/2014 - Page 10 

 
The system is generally compatible with most reflectors of the Bowens / S-Line as well as 
HENSEL  /  E  and  EH  series.  As  for  HENSEL  reflectors,  the  clamps  fit  around  the  raised 
edge  of  the  reflector  from  the  outside.  Should  you  have  any  questions  concerning 
compatibility, please contact us. 
 
Connection of softboxes to flash heads 
The  PRIOLITE  softboxes  have  a  speedring  which  is  mounted  to  the  reflector  locking 
mechanism  of  the  flash  head  the  same  way  as  reflectors  (see  description  above).  For 
softboxes of other brands adapters are available upon request. Please ask for details. 
 
Umbrella attachment to flash heads 
To  attach  an  umbrella  to  the  flash  head insert  the  rod  in  the  round opening  at  the  front of 
the rail profile to the desired length and tighten it using the knurled screw. 

 

Acclimatization 
If  the  flash  units  are  to  be  set  up  at  a  new  location  with  a  different  humidity  level  and/or 
temperature, the units should stand for a while before operation in the room in which it is to 
be  used.  This  should  prevent  the  formation  of  leakage  current  which  can  develop  due  to 
precipitation. 
 
Overheating 
All  units  are  equipped  with  a  fan  to  prevent  damage  to  the  flash  tube  and  the  unit  itself 
during long series of flashes. Nonetheless, should overheating occur, an error message will 
appear  on the LED  display.  The  error  message  will  be automatically  reset  as  soon as the 
unit has cooled down. 
 
Starting up 
 
The flash head does not have a main switch. Before starting-up, the flash head cable has to 
be  connected  to  the  generator  by  connecting  the  plug  into  the  socket  of  the  power  pack. 
This  is  done  by  clockwise  turning  the  plug  into  the  bayonet  lock.  After  switching-on  the 
power pack, the flash head is ready to flash. 
 

Before each operation, the black plastic transportation cap has to be removed. 
 
Each  power  pack  provides  only  one  socket  for  flash  head  connection.  Only 
operation  of one  PRIO  HEAD  1000  per  generator is approved.  The  flash  head  is 
suitable for both types of power packs (M-PACK 500 and M-PACK 1000 (HS)). 
 

The  power  pack  is  switched  on  and  off  by  pressing  the  main  switch  protected  by  a  flap 
against unintentional switching. 

Содержание M-PACK 1000 (HS)

Страница 1: ...PRIOLITE GmbH Gattingerstr 7 D 97076 W rzburg Tel 49 0 931 20700000 eMail info priolite com http www priolite com Instruction manual Instruction manual M PACK HS PRIO HEAD M PACK HS PRIO HEAD...

Страница 2: ...ITE GmbH Wuerzburg Last revised 08 2014 Page 2 USER MANUAL Technical data are subject to change No guarantee for misprints The listed values are guide values and should not be understood as binding in...

Страница 3: ...g of accessories to flash heads 9 Connection of reflectors to flash heads 9 Connection of softboxes to flash heads 10 Umbrella attachment to flash heads 10 Acclimatizing 10 Overheating 10 Starting up...

Страница 4: ...power pack The PRIO HEAD 1000 is intended for connection to the M PACKs and works with both types of generators 500 and 1000 The power packs power output ranges from a minimum level of 16J up to a ma...

Страница 5: ...ype of maintenance work or before transports which may be undertaken on the units only when they have been switched off separated and after the waiting period has expired Contact with the capacitor vo...

Страница 6: ...ames with water but use sand Damaged Lithium ion batteries are readily to be disposed of in appropriate containers Lithium ion batteries contain flammable and or corrosive solutions and Lithium salts...

Страница 7: ...1 200 sec with focal plane shutter cameras 1 800 sec with central shutter cameras M Pack 1000 HS 1 8000 sec using RC HS C N P Sync voltage 5V for safe flash triggering by modern digital cameras socke...

Страница 8: ...ist height 3 The power pack can be stored for transportation purposes in the PRIOLITE gear tube accessories not included in the standard delivery hanging around the shoulder In the gear tube the power...

Страница 9: ...s dome straight off Mounting of accessories to flash heads Light modifiers reflector soft box umbrella etc are to be mounted to flash heads before the units are put into operation Accordingly the powe...

Страница 10: ...the units should stand for a while before operation in the room in which it is to be used This should prevent the formation of leakage current which can develop due to precipitation Overheating All u...

Страница 11: ...manipulation on connectors and or sockets are to be made Only spare parts from PRIOLITE are to be used Replacement of battery drawers For battery replacement please proceed as follows Before exchangi...

Страница 12: ...l Control knob The control knob is used to set the desired flash power in 1 10 increments from a minimum of 16V to a maximum of 500J M PACK 500 or 1000J M PACK 1000 HS covering 6 f stops for M PACK 50...

Страница 13: ...il the desired selection is indicated on the LED display By adjusting all possible combinations a maximum of 36 PRIOLITEs LED 400 series M MB MBX M PACK can be individually controlled Team and ID can...

Страница 14: ...curs when a flash from another unit strikes the first unit This operating mode is activated by pressing the Slave button control LED is on The photocell is designed as an impulse photocell Thus it wor...

Страница 15: ...efully out of the plug connector and replace it with a new one to be ordered from PRIOLITE by plugging the three contacts into the sockets Before using the unit once again the glass dome is to be moun...

Страница 16: ...ww priolite com Declaration of Conformity The company PRIOLITE GmbH Gattingerstr 7 D 97076 W rzburg Germany declares that the products M PACK 500 M PACK 1000 HS and PRIO HEAD 1000 are in conformity wi...

Отзывы: