Performance Guidelines:

Performance of the appliance such as pressure boost or flow rate of the connected R.O. unit is 
highly dependent on local conditions (inlet water pressure, temperature and TDS, R.O. membrane 
type and flow rating, R.O. unit type and its design specifics) and R.O. system use pattern.

Typical pressure boost (

P, extra pressure built upon the inlet pressure) is up to 50 psi 

(0.34 MPa) for 50-100 GPD R.O. membrane for X845, and up to 100 psi (0.69 MPa) for 
150-500 GPD membrane for X855. For example, the higher the GPD rate of the membrane 
attached or the higher the water temperature the lower is an actual pressure boost for 
a given setup but the higher the output flow rate in working mode. Typically, in working 
mode outlet water pressure reaches 80-110 psi for X845 and 110-160 psi for X855 
depending on local conditions and membrane used.

Drain water flow restrictor: 300 cc (ml/min) nominal, up to 450 cc in working mode, open 
flow in flush mode.

Auto-flush duration: 18±10% s

Idling protection: 120 minutes (the unit will shut-off the pump and goes into ‘reset required’ 
mode if working mode continuous duration reaches 2 hours without interruption)

Warranty:

1 year limited warranty

Package Contents:

(1) The auto-flush booster pump box unit

(20 ft / 6 m) Water tubing ¼”

(1) ¼” x ¼” x ¼” union tee quick fitting

(1) ¼” x ¼” union check valve

User’s guide

Installation
Notes:

1. Install your R.O. machine first. Usually, steps include: inlet valve installation, drain saddle 
installation, filtered water faucet installation, tank and tank valve installation, etc. See your 
R.O. machine manual for the detailed instructions. Do not open inlet valve until you finish the 
unit setup. If you used your R.O. machine before close the inlet valve and drain the water tank 
(by opening the filtered water faucet).

2.  If  your  R.O.  machine  includes  flow  restrictor,  4-way  shut  off  valve,  manual  flush  valve 
remove them on the R.O. unit itself. Built-in components of the pump box will be used instead. 
See the following charts for proper connection scheme.

3. Use of air gap faucet is not recommended in R.O. systems with powerful auto flush feature 
due to high flow of waste water during the flush. If you have air gap faucet you may simply not 
use its waste line and insert waste water tubing directly into the drain saddle (bypassing the 
air gap). You may want to use a check valve (optional) on the drain line then to obtain same 
protection from a drain water backset as air gap provides.

4. During installation you will need to cut the supplied ¼” tubing into segments as needed. 
Use your utility knife for that or similar tool. See the following charts to determine the 

Содержание Prio Jet X845

Страница 1: ...ide Model X845 External Booster Pump Box with Auto Flush for 50 100GPD Reverse Osmosis Filtration Systems Model X855 External Booster Pump Box with Auto Flush for Direct Flow Tankless Reverse Osmosis...

Страница 2: ...cing your water filter system and changing the membrane or filters Do not use the appliance if operating requirements such as water temperature water pressure electrical supply etc are not met Follow...

Страница 3: ...debris build up on the membrane outer surface Powerful booster pump increases pressure to radically improve the performance and effectiveness of the R O unit in all three key areas increases filtered...

Страница 4: ...d is full The pump is off No action is required Flush 18 s membrane flush is going No action is required Reset idling protection was triggered The pump is off To restore normal operation power cycle t...

Страница 5: ...iciency rate less water is treated overall by pre filters and the membrane for each gallon of permeate produced This saves the capacity of pre filters and ensures either less frequent change necessity...

Страница 6: ...e auto flush booster pump box unit 20 ft 6 m Water tubing 1 x x union tee quick fitting 1 x union check valve User s guide Installation Notes 1 Install your R O machine first Usually steps include inl...

Страница 7: ...valent is still recommended prior to the unit point of entry sediment filter works just fine for this purpose 6 Do not connect the unit to the electrical supply until the Setup is completed IMPORTANT...

Страница 8: ...nlet fitting of the unit 2 Insert the supply tubing from the RO unit fitting of the unit into the supply inlet of the membrane housing 3 Insert the filtered water tubing from the filtered water outlet...

Страница 9: ...e side outlet union tee tting pre lter s X845 X855 with tank tank valve union tee tting General R O System with Tank Connections from nal pre lter outlet to supply inlet of the membrane from ltered wa...

Страница 10: ...drain saddle union tee tting X855 direct ow General Direct Flow R O System Connections from nal pre lter outlet to supply inlet of the membrane from ltered water outlet of the membrane from waste wat...

Страница 11: ...O600 tank inlet valve waste water outlet permeate outlet to the tank union tee tting from waste water outlet of the membrane to drain or waste water collection container check valve ltered water fauce...

Страница 12: ...outlet permeate outlet R O unit inlet inlet valve drain saddle MOD600 ltered water faucet from inlet valve to R O unit inlet from ltered water outlet of the R O unit from waste water outlet of the R...

Страница 13: ...tlet waste water outlet of the membrane side permeate outlet of the membrane center membrane inlet X855 Prio Expert OD360 Direct Flow R O System Connections from nal pre lter outlet to supply inlet of...

Страница 14: ...nit s power cord into the electrical outlet wait for water to arrive at the faucet it may take a while water foam and air may be going out of the system wait 2 minutes for more or less steady water fl...

Страница 15: ...The pump will turn on automatically and will produce the filtered water flow in real time until you close the faucet At the end of each water production cycle the membrane will be flushed and then th...

Страница 16: ...io logo are the trademarks of DWT Deutsche Wassertechnologien GmbH Germany As used herein denotes registered trademark status in Germany only Copyright DWT Deutsche Wassertechnologien GmbH Germany 201...

Отзывы: