44
Chapter
2
Configuring The ANSI Emulation
Purpose
Line terminator. Moves the current vertical position by the
specified
p1
number of decipoints as shown in Table 9.
Vertical Tab Set
ASCII Code
ESC [
p1
;
p….
; v
Hex Code
1B 5B
p1
3B p… 3B 76
Dec Code
27 91
p1
59 p… 59118
Purpose
Set up to 12 vertical tabs. The tabs values are in decipoints. If
more than 12 tabs are set, the 12 tabs nearest to the top of form
will be retained. If a tab is set in the top margin, it will be stored,
but not active until the margin is moved. If a tab is set beyond
the bottom margin, an attempt to move to that tab will move the
paper to the next top of form.
Table 9. Vertical Position
Decipoint Value
Movement in Inches
missing or 0-4
no movement
5-9
1/144 inch
10-14
2/144 inch
15-19
3/144 inch
...
15, 840 or greater
...
22 inches