Panther T14R - Operation and maintenance manual
LATERAL CONSOLE
40/178
Smartemp Control fx / Operation instructions
Definition
Default
Time and date
Time & Date allows user to properly set the current date and time. User also has the ability to
switch between AM/PM and 24 hour modes.
AM/PM
(12 hour)
Mode
Two modes are possible:
- Auto mode will allow the heater to turn ON/OFF based on the pre-defined timer pro-
grams.Manual ON/OFF operation is still possible while in this mode.
- Manual Mode allows the heater to be manually operated via the Webasto button on the
SmarTemp Control fx. While in Manual Mode, all Auto Mode functionality is disabled (Timers-
inactive).
Note: While in manual mode the heater will continue to operate based on the pre-defined
"Duration" set by the user.
Manual
Duration
Duration allows for the selection of timed heater run-time. Set range is between 10 - 120 min-
utes selectable by 10 minute increments.
While using Manual Mode, the "Duration" setting will be used for the run-time of the heater
when the Webasto button is pressed.
60 minutes
Timer
Timer allows the user to set 4 heater start-up cycles per day up to 7 days in advance. Select
the day or the specific timer program (T1 - T4) using the rotary knob and the selection button.
Once the day, time, and duration have been entered, press the selection button to set. A
checkmark will confirm the program has been saved. Each program can be edited or
removed simply by selecting the box again.
Note: Setting the Duration run-time before setting a timer program will default all new pro-
grams to the user defined duration time.
No presets
Skip
The Skip feature looks similar to timer programming; however when a specific timer program
is selected, it will update the checkmark to an "s" for skipped. When a program has been
skipped, it will disable that specific timer program for one cycle (7 day period). Preset timer
programming will reactivate after this one-time skip cycle.
N/A
LVD
LVD "Low Voltage Disconnect" allows the user to adjust the battery voltage level at which the
Webasto SmarTemp Control fx will shut down heater functionality. If battery voltage is equal
to or less than the threshold se0.1v, the heater will not start. i.e. if an 11.5v threshold
is selected the heater cannot be started until B+ has reached 11.7v.
12 volt - Range between 11v - 12.5v
24 volt - Range between 21v - 25.5v
12.1 v
24.2 v
Error codes
This section will log the last 5 error codes and the date that it was set. Highlight and select an
error code for a full description.
If the heater produces an error code, the status indicator lights will flash red and the error will
display on the main screen. Error codes cannot be reset through the Webasto SmarTemp
Control fx. Refer to the heater service manual for resetting an error code.
Note: Error code functionality does not apply to Thermo Top C heaters. Errors codes for this
product can still be obtained using PC Diagnostics. Refer to the applicable service manual by
visiting www.techwebasto.com for detailed PC diagnostics information
No errors
Hour meter
The hour meter logs the operating hours that the heater is commanded "ON" from the Smar-
Temp Control fx.
Note: For warranty purposes a diagnostic printout is still required where applicable. This hour
meter is for reference only
N/A
Default
Default allows the user to perform a factory reset of the control settings and saved timer pro-
gram data.
N/A
SW version
This displays the firmware version of the Webasto SmarTemp Control fx.
Installed version
Back
Select this to return to the previous screen.
N/A