CONNECTING TRANSFORMERS
Attach Qwik Boxes to available support member. See
Qwik Box install guide.
Connect power supplies to primary wiring.
Install strain relief for low voltage wire.
Drill 1/2” hole through the fascia. A conduit fitting can be
installed so that conduit can be used.
Insert low voltage wire into the hole and connect to LED.
Fill hole with silicone sealant.
Note: Stop and make sure the supplied power supply is
277VAC rated with any primary voltage greater than 120.
1.
2.
3.
4.
5.
Note: Four 96” Street Wrap™ Border per 96W Power Supply.
Side by side mounting location shown below can reduce
primary and secondary wiring labor time.
VERY IMPORTANT:
KEEP LOW VOLTAGE CIRCUITS ELECTRICALLY SEPARATE, DO NOT CONNECT TRANSFORMERS OR LEDs FROM DIFFERENT 96” STREET WRAP
GEN 2™ TOGETHER OR CONNECT MORE THAN FOUR 96” STREET WRAP GEN 2™ TO A 96W POWER SUPPLY!
Primary 100-277VAC (IN)
Secondary 24VDC
Low Voltage (OUT)
TO
LEDS
Fascia
DO NOT
CONNECT
HIGH VOLTAGE
TO LEDs. LEDs
ARE 24VDC
ONLY!
24 VDC
Low
Voltage
96”
96”
8
Main
Breaker
Main
Breaker
Connect Black and White
wires from Power Supplies
to 100-277 VAC
Connect Red and Black Low
Voltage Wires from
Transformers to LEDs
Power Cable Strain
Relief Fitting