Press the “Mode“ button till the “Cool“ icon appears.

Press the

 or 

 button to select a desired room

temperature.

Allow around 5 minutes for the cooling to start.

Press the “fan speed” button to adjust airflow.

Dehumidifying operation

Press the “Mode“ button until the “dehumidify indicator lamp“
blinks.

The temperature will automatically be selected.

The fan speed will automatically be selected.

Timer operation
Timer ON setting

When the air-conditioner is OFF, press the “Timer“ button and
select a desired ON time and adjust using the temperature
buttons.

The ON time can be adjusted to anytime in 0-24 hours.

Timer OFF setting

When the air-conditioner ON, press “Timer“ button and select a
desired OFF time through the temperature buttons.

The OFF time can be adjusted to anytime in 0-24 hours.

Drainage

After a lengthy operation and before storage, you will need to
drain the water that has been collected. Please prepare a
suitable location or tray to collect the water and remove the
rubber stop from the drainage hole at the bottom of the unit. The
water will then begin to drain. After this has stopped, you can
insert the drain stop.

Internal Tank Water Full Alarm Function

The inner water tank in the air-conditioner has one water level
safety switch that controls the water level. When the water level
reaches an anticipated height, the water full indicator lamp lights
up. Follow above steps to drain the water.

INSTALLATION

The air-conditioner should be installed on a flat and stable
surface. Do not block the air outlet and allow at least 30cm
around the unit.

Socket wiring should be in accordance with the local electric
safety requirements.

EN

Содержание 01.352103.02.001

Страница 1: ...EN Instruction manual Air conditioner 01 352103 02 001 ...

Страница 2: ...PARTSDESCRIPTION ...

Страница 3: ...supply Always turn off and disconnect the power supply before moving the unit WARNING To avoid the risk of fire do not cover the unit All the unit sockets must comply with the local electric safety requirements If necessary please check If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard If the supply cor...

Страница 4: ...installed operated and stored in a room with a floor area larger than X m2 X 4 for 5000Btu h 7000Btu h 8000Btu h X 7 7 for 9000Btu h 10000Btu h 10500Btu h Only contact an authorized service technician for repair or maintenance of this unit Do not pull deform or modify the power supply cord or immerse in water Pulling or misuse of the power supply cord could result in damage to the unit and cause a...

Страница 5: ...is appliance contains Y g see rating label back of unit of R290 refrigerant gas R290 is a refrigerant gas that complies with the European directives on the environment Do not puncture any part of the refrigerant circuit If the appliance is installed operated or stored in a non ventilated area the room must be designed to prevent to the accumulation of refrigerant leaks that could result in a fire ...

Страница 6: ...n as possible with clean water without rubbing your eyes Immediately go to the hospital If it is not treated properly it can cause eye problems Refrigerant CE N 842 2006 This unit contains the refrigerant R290 The amount of refrigerant is less than 1kg and is in a closed cooling circuit The coolant does have zero ozone depletion potential but is a so called greenhouse gases under the Kyoto Protoco...

Страница 7: ...Instruction manual 7 FUNCTION OF CONTROL PANEL 1 Power on off button 2 Temperature buttons 3 Mode button 4 Fan speed adjustment button 5 Timer on off button EN ...

Страница 8: ...ly nearby Install the exhaust hose and adjust the window position well The supplied small white clips must be mounted on the window kit Insert the power cord into a grounded AC220 240V 50Hz socket Press the power button to turn on the air conditioner Set the temperature range 16 C 31 C Check whether the exhaust hose has been mounted properly When using functions on cooling and dehumidifying allow ...

Страница 9: ...mperature buttons The OFF time can be adjusted to anytime in 0 24 hours Drainage After a lengthy operation and before storage you will need to drain the water that has been collected Please prepare a suitable location or tray to collect the water and remove the rubber stop from the drainage hole at the bottom of the unit The water will then begin to drain After this has stopped you can insert the ...

Страница 10: ...e hose connector air conditioned end 10 into the openings at the back of the air conditioner Fix the hose connector window end 8 to the nearest windowsill Window Slider Kit Installation Adjust the width picture 1 or height picture 2 of the windows slider 11 to fit the window opening and fixate the position of the windows slider 11 with the fixing plugs Slide the window up to the slider ...

Страница 11: ...cals to clean the unit Do not wash the unit directly Use a vacuum with a brush attachment to clean the coils and take care not to damage the coil fins during this process Air filter The air filter should be cleaned once every two weeks Open the air inlet grille and take off air filter Clean the air filter with neutral detergent in lukewarm 40 C water and allow to dry not in direct sunlight Re inst...

Страница 12: ...ill power off automatically Allow room temperature to cool before re starting the unit Noisy The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner Place unit on a flat level ground if possible E0 Code Room temperature sensor failed Replace room temperature sensor E2 Code Water tank full Please empty the water tank THE PRODUCT OR E...

Страница 13: ......

Страница 14: ...0 Jules Verneweg 87 5015 BH Tilburg The Netherlands www princesshome eu IN NEED OF ACCESSORIES VISIT WWW PRINCESSHOME EU NL NL CUSTOMERSERVICE ACCESSORIES SPAREPARTS FOR ACCESSORIES AND SPARE PARTSTO EXTENDYOUR ITEM ...

Отзывы: