Prince Castle Merlin II 840-C Series Скачать руководство пользователя страница 8

ENTER

1A=REMOVE

2 : 0 0

5. The scan feature is used to check the time values on

other active channels.  There are two different ways

to scan active channels.  Press the 

SCAN/UP

 or

SCAN/DOWN

 button.Or press any of the active

TIMER

 

CHANNEL

 buttons.  If no other button is

pressed within 5 seconds, the display will change to

show the timer with the least amount of time left.

6.You can change the sound level of the alarm in 

RUN

MODE

.  Press and hold the 

PRINCE CASTLE

LOGO

 ; then, within six seconds, press either the

SCAN UP

 

BUTTON

 or the 

SCAN DOWN

 

BUTTON

.

The 

SCAN UP

 

BUTTON

 adjusts the sound level to

the louder alarm, and the 

SCAN DOWN

 

BUTTON

adjusts the sound level to the lower alarm.

VII CLEANING

1. Do not allow grease to build up on the timer, wipe it

down daily with clean damp cloth.

IMPORTANT:

 Do not use abrasive or chemical cleaners

on your timer, this may cause damage to the overlay.

VIII PART LIST

 

ITEM

PART NUMBER

 DESCRIPTION

1

  69-079S

 Rivet Plastic Push Pin

2

  840-100

 Rear Cover

3

    840-134S

 Main P.C.Board

    840-109S

 Auxillary P.C.Board

(840-C8D & 840-C16D)

4

        71-042-02S

 Display Board

5          88-653-2-7S

 Speaker Assy.

6

     840-096S

 Switch Panel Assy.

 (840-C8 Series)

    840-110S

 Switch Panel Assy.

 (840-C4 Series)

7

   70-048S

 Knob W/Washer (Pkg of 2)

     8

   840-103

  Chassis  (840-C4  &  C8)

   840-115

  Chassis

 (840-C8D & C16D)

     9

     72-292S

 Power Supply (110V)

           72-293-01JS

 Power Supply (100V)

            72-293-04FS

 Power Supply (220-240V)

*

10

840-140

Left Probe Connector

840-141

Right Probe Connector

*

Not Shown

VI   OPERATION

1. Press a channel button to activate a timing cycle.

(All channels can be activated and running at the

same time.)  The  channel with the least amount of

function time remaining will be displayed in the

FUNCTION DISPLAY

 along with its next function.

The time remaining will countdown in the 

TIME

DISPLAY

, and the time value 

M:S

 or 

H:M

 will be

illuminated.

2. Press the desired channel button three times within

five seconds to cancel an active timing cycle.

IMPORTANT:

 The channel timer button’s multi-

colored LED indicator shows the status of the

timer. The indicator has three colors: green,

yellow, and red.  The LED will be green during

the first 70% of the countdown.  It changes to

yellow during the next 20% of the countdown.  It

will be red during the final 10% of the countdown,

and will start flashing red once the time has run

out.

Note:

 If a Manual Cancel is programmed into a

duty function the LED will flash red until the

channel button has been pressed . If an Auto-

matic Cancel is programmed  the LED will flash

green for 5 seconds and the alarm will automati-

cally turn off.

3. The timer will countdown from the programmed

value to zero.  When the complete cooked time is

finished, the TIME DISPLAY  flashes 

0 0 

and the

alarm sounds.

4. When the timing cycle is complete, and the alarm

sounds, press the channel button with the flashing

red indicator to cancel the alarm.

8

Printed in USA 3/06 © 2006 

840-50

9

rev

A

Содержание Merlin II 840-C Series

Страница 1: ...This equipment is portable charges for on location service e g trip charges mileage are not included in the provisions of this warranty This warranty is subject to the following exceptions conditions...

Страница 2: ...2 7853 if purchased directly 2 Verify that all parts have been received Mounting bracket and hardware are provided 3 To mount the timer place mounting brackets in de sired location Scribe location of...

Страница 3: ...TON to switch from one mode to the other Press the ENTER button to store your selection or if no change is required Press either the SCAN UP BUTTON or the SCAN DOWN BUTTON to switch through the four p...

Страница 4: ...dD1T DUTY1 TIME and the TIME DISPLAY will show the current Duty Time 9 Press the SCAN UP or SCAN DOWN ARROWS to adjust the time setting Note If no duty time is desired set the time to 00 00 Press the...

Страница 5: ...h from one temperature scale to the other Press the ENTER BUTTON to store the chosen temperature scale 4 All of the channel LED s will be lit and SEL CHAN PROBE will be in the display A GREEN LED desi...

Страница 6: ...LAY and the probe temperature in theTIME DISPLAY 5 Use a thermometer to measure the actual fryer temperature 6 Press either the SCAN UP or SCAN DOWN BUT TON to change the offset value so that the temp...

Страница 7: ...TTONto begin theRECOVERY TIME CHECK PrA 275F WAIT or PrA 135C WAIT will appear in the FUNCTION DISPLAY and 00 in the TIME DISPLAY until the shortening reaches275 F 135 C 5 When the temperature reaches...

Страница 8: ...upply 100V 72 293 04FS Power Supply 220 240V 10 840 140 Left Probe Connector 840 141 Right Probe Connector Not Shown VI OPERATION 1 Press a channel button to activate a timing cycle All channels can b...

Страница 9: ...s are in stop mode mode Logo Switch inoperable Replace Switch Panel D Unit enters program mode The channel is still counting Wait until channel is in stop mode but cannot change times Arrow Switch ino...

Страница 10: ...X WIRING DIAGRAM 10 Printed in USA 3 06 2006 840 509revA...

Отзывы: