14
INSTALLATION, MAINTENANCE AND USER' MANUAL
540889_PUB_DATE_1_JUL_2011.DOC
Operation
First service at technical problem
N°
Failure message
Failure
Action
Fault occurrence
E2
No Drain
Drain failure
Full Stop + tumble
Draining sequence
E3
Tilt Fault
Out of balance
Full stop + tumble
Whole cycle
E4
Imbalance
Out of balance : Normal
spin
Skip + continue
After 5 attempts to spin
E5
Tilt High Sp
Out of balance : high
spin
Full stop + safety time
>500 or 750 RPM
E6
Door Coil
Door switch failure
Full stop + safety time
Whole cycle
E7
Door Switch
Door solenoid switch
failure
Full stop + safety time
Whole cycle
E8
Door Start
Door lock check at start
failure
Don’t start
At start up
E9
Door Unload
Door lock switch closed
failure
Don’t start
End cycle
E11
No Fill
Fill failure
Full stop + request for
Continue
While filling
E12
Overfill
Overfill failure
Full stop + tumble
While filling
E13
No Heating
Heating failure
Full stop + tumble
While heating
E14
Heat Time
Heating time failure
Full stop + request for
Continue
While heating
E15
Too Hot
Too Hot
Full stop + tumble
While heating
E21
Overflow
Overflow failure
Full stop + tumble
Wash step
E24
Level Sens
Defective level sensor
Co Don’t start
Before start up
E25
Temp Sensor
Defective temperature
sensor
Co Don’t start
Before start up
E26
Mitsub code
Undefined frequency
inverter error code
Full stop + tumble
Whole cycle
E27
Comm fault
Communication fault
inverter
Full stop + safety time
Whole cycle
E28
THT time / E.OL
THT Time out / E.OL
Full stop + safety time
At spin sequence
E29
OV3 time / E.OP
OV3 Time out / E.OP
Full stop + safety time
At spin sequence
E31
Load Parr
Initialization fault
inverter
Don’t start
At initialization
E32
Verify Parr
Verification fault
inverter
Don’t start
At loading parameters
E35
Wrong Softw
Wrong software version Don’t start
New software version
E37
No Drain Sp
Drain failure at the
Spray Sequence
Full stop + tumble
Spray Sequence
E39
Out of Soap
The Soap Supplies are
running Out of Soap
For Info only
Wash step
E41
Service Due
Service Due Warning
For Info only
Open door = reset
End cycle
E42
Connection
No Network
Connection
For Info only
Data Transfer Networking