Cabinet Temperature – Setting
The temperature may be set independently
for each zone in the range -18° to +10°C.
Setting the left zone
1. Press the mode button once (1)
and
the temperature display will flash with the
current setting.
2. Adjust the temperature by pressing up
to increase and down
to decrease until
the desired temperature is reached
3. The selected temperature will flash on the
display for 3 to 5 seconds before displaying
the current cabinet temperature
Setting the right zone
1. Press the mode button twice
and the
temperature display for the right zone
will flash with the current setting.
2. Adjust the temperature by pressing up
to increase and down
to decrease until
the desired temperature is reached
3. The selected temperature will flash on the
display for 3 to 5 seconds before displaying
the current cabinet temperature
Shutting Down a Selected Zone
The Flexi Zone + cooling system will allow either
zone to be shut down independently to the other.
This is perfect for when the total cabinet space
is not required and provides improved power
efficiencies.
1. Press and hold the up button
and
the left zone will shut down
2. Repeat the same step and the left zone
will recommence operation
3. Press and hold the down button
and
the right zone will shut down
4. Repeat the same step and the right zone will
recommence operation
Left zone may be set to the same
temperature as the right zone
Left zone may be set to a warmer
temperature than the right zone
Left zone may be set to a cooler
temperature than the right zone.