Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
NOTE: When replacing motor, motor switch
should be at 10 o’clock position. The positioning tab
on the motor should be engaged with the anti-
rotating notch in the motor bracket.
m. Motor Connection Block Terminals
Remove terminals from the motor wire harness
connection block using No. 283P4 Terminal
Extractor Tool as follows:
(1) Insert the tool into the block on the back of
the terminal being removed. Refer to
Figure 51.
(2) Apply tool pressure to compress the
terminal locking tab on terminal and force
the terminal and wire out back side of
connection block. Refer to Figure 51.
To install terminal in connection block, insert
terminal (with wire securely crimped in place)
into back side of connection block. Push
terminal into connection block until locking tab
on terminal spreads and holds terminal in place.
Figure 51
CONNECTION
BLOCK
283P4
TERMINAL
EXTRACTOR
TOOL
TERMINAL
LOCKING
TAB
D251SE3A
Содержание DAM 9
Страница 1: ...DAM 9 SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 02 01 516514 ...
Страница 2: ......
Страница 24: ...22 516514 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 90: ...88 516514 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 126: ...124 516514 Section 8 Wiring Diagrams Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 127: ......
Страница 128: ......