3. Handling the appliance
3.1 Be careful not to touch the hot parts of the
appliance during or after use.
3.2 Storage: Always unscrew the cartridge or
liquid fuel bottle from the appliance when not
in use. Store the cartridge or bottle In a safe,
dry place away from heat.
3.3 Do not misuse the appliance, or use it for
any purpose other than that intended.
3.4 Handle the appliance with care. Do not
drop it.
4. Assembling and operating
the appliance with a gas
cartridge (fig. 2 and 4)
4.01 It is absolutely essential that the
fuel line be completely clear of liquid fuel
when cartildge gas Is used, otherwise a
dangerously high flame wIll result! (Soo
6.8.7 for instructions on how to drain the
fuel system.) Also ensure that a 0.43 mm jet
Is installed.
4.1 Ensure mat the shut-off valve (2) and gas
control (5) are fully closed (by turning the knob
fully clockwise).
4.2 Keep the cartridge (3) upright when fitting
it to the valve.
4.3 Place the valve squarely on top of the
cartridge (as shown in Fig .2).
4.4 Screw the cartridge carefully into the valve
until it meets the O-ring, taking care not to
cross-thread the cartridge. Hand cartridge
valve may be damaged.
4.5 Ensure that the gas seal is tight. Carry out
checks outdoors.
NEVER
use a naked flame
to check for leaks. Apply warm, soapy water
to the joints and connections, and observe
for leak. In the form of bubbles around the
suspect area. If in doubt, or if an escape of
gas can be heard or smelled, do not attempt
to light the appliance. unscrew the cartridge
and contact your local dealer.
4.6 Swing the legs (pan supports) (12) into
position in the wind shield (11).
4.7 The stove is now ready for use.
4.8.1 Always place the appliance on a steady
surface. Ensure that the hose is fully extended,
and that it is run straight between the cartridge
and stove. Keep the cartridge clear of the heat
of the appliance.
4.8.2 First turn the shut-off valve (2), then the
gas control (5) counterclockwise and light the
burner (4) immediately.
4.8.3 Adjust the tame using the gas control (5)
or shut-off valve (2).
4.8.4 After lighting, keep the appliance upright
and do not move it around. A high flame may
occur if the appliance has not been preheated
fully or if it is moved without care.
4.8.5 After use, first close the shut-off valve
(2). When the fame Is extinguished, also close
the gas control (5).
4.8.8 A minimum clearance must be
maintained with flammable materials. The
minimum permissible clearance between
the appliance and ceiling, and between
the appliance and the nearest wall, is 1250
mm.
These minimum clearances must be
observed to prevent a fire hazard.
5. Changing the cartridge
5.1 Close the shut-off valve (2) End gas control
(5) fully. Ensure that the flame is extinguished
and that there is no other flame source in the
vicinity. Change the cartridge outdoors away
from other people. Unscrew the cartridge
from the valve and replace the 0- ring seal if
cracked or worn. Avoid cross-threading by
placing the valve squarely on the cartridge
thread, and hand-lighten only as described in
section 4.