PrimoPal PSR8078 Скачать руководство пользователя страница 5

                                                                                       

PSR8078 User Manual

 

REV1.0                                                                  5 

5. Connecting the Motor 

The stepper drive PSR8078 can drive any 2-pahse and 4-pahse hybrid stepping motors.   

5.1 Connections to 4-lead Motors 

4-lead  motors  are  the  least  flexible  but  easiest  to  wire.  Speed  and  torque  will  depend  on 
winding inductance. In setting the drive output current, multiply the specified phase current 
by 1.4 to determine the peak output current. 

 

Figure 4: 4-lead Motor Connections 

5.2 Connections to 6-lead Motors 

Like 8-lead stepping motors, 6-lead motors have two configurations available for high speed 
or  high  torque  operation.  The  higher  speed  configuration,  or  half  coil,  is  so  described 
because it uses one half of the motor’s inductor windings. The higher torque configuration, or 
full coil, uses the full windings of the phases. 

5.2.1 Half Coil Configurations 

As previously stated, the half coil configuration uses 50% of the motor phase windings. This 
gives  lower  inductance,  hence,  lower  torque  output.  Like  the  parallel  connection  of  8-lead 
motor,  the  output  torque  will  be  more  stable  at  higher  speed.  This  configuration  is  also 
referred to as half chopper. In setting the drive output current multiply the specified per phase 
(or unipolar) current rating by 1.4 to determine the peak output current. 

 

Figure 5: 6-lead motor half coil (higher speed) connections 

                                                                                         

PSR8078 User Manual

 

REV1.0                                                                  6 

5.2.2 Full Coil Configurations 

The  full  coil  configuration  on  a  6-lead  motor  should  be  used  in  applications  where  higher 
torque at lower speed is desired. This configuration is also referred to as full copper. In full 
coil mode, the motors should be run at only 70% of their rated current to prevent overheating. 

 

Figure 6: 6-lead motor full coil (higher torque) connections 

5.3 Connections to 8-lead Motors 

8-lead  motors  offer  a  high  degree  of  flexibility  to  the  system  designer  in  that  they  may  be 
connected in series or parallel, thus satisfying a wide range of applications. 

5.3.1 Series Connections 

A series motor configuration would typically be used in applications where a higher torque at 
lower  speed  is  required.  Because  this  configuration  has  the  most  inductance,  the 
performance will start to degrade at higher speed. In series mode, the motors should also be 
run at only 70% of their rated current to prevent overheating. 

 

Figure 7: 8-lead motor series connections 

Содержание PSR8078

Страница 1: ...ribed without being sure to have understood characteristics installation and use procedures Even though products described have been designed with extreme care they are not intended or authorized for...

Страница 2: ...Connections to 6 lead Motors 5 5 2 1 Half Coil Configurations 5 5 2 2 Full Coil Configurations 6 5 3 Connections to 8 lead Motors 6 5 3 1 Series Connections 6 5 3 2 Parallel Connections 7 6 Power Sup...

Страница 3: ...is widely used in various kinds of machines such as CNC routers cutting machines packing devices pick place devices and so on Particularly suitable for the applications require low cost low noise low...

Страница 4: ...level signal correlative to motor rotation direction For reliable response DIR must be ahead of PUL by 5 s at least 4 5V when DIR HIGH 0 0 5V when DIR LOW Motor rotation direction also depends upon th...

Страница 5: ...ed This configuration is also referred to as half chopper In setting the drive output current multiply the specified per phase or unipolar current rating by 1 4 to determine the peak output current Fi...

Страница 6: ...avoiding losing steps However higher voltage may cause bigger motor vibration at lower speed and it may also cause over voltage protection or even drive damage Therefore it is suggested to choose only...

Страница 7: ...PrimoPal Motor 8 Wiring Notes In order to improve anti interference performance of the drive it is recommended to use twisted pair shield cable To prevent noise incurred in Pulse Direction signal Puls...

Страница 8: ...ocess You may need this documentation to refer back to at a later date and these details will greatly assist our Technical Support staff in determining the problem should you need assistance Many of t...

Страница 9: ...to the product itself and does not cover any damage caused by the product 12 3 Obtaining Warranty Service To obtain warranty service a returned material authorization number RMA must be obtained from...

Отзывы: