DRAFT
5. If the RTC clock is off significantly, the Transceiver it enters a critical error state, its front panel LED Error status indicator is
illuminated, and transmits its state to OneVue at its scheduled check-in. Only occurs after the first 30 minutes of operation if the
RTC continues to be significantly off.
Transceiver power failure
During a power failure, the Transceiver continues to track time with the last valid time signal that it received. Once the power had
been restored, the Transceiver begins to broadcast (even without a valid time signal) to the down-stream components. Once the
Transceiver has been powered on for a few hours, it's capable of keeping track of time off its internal backup power for up to eight
hours.
l
The system has a fail-safe design. If the failure of a system component or power loss to a component occurs, all down-stream
components continue normal operations using their own internal time base.
l
If after a specified period of time communication has not been restored, a visual indicator on its front panel is illuminated and its
state is sent to OneVue during its next scheduled check-in. It remains in this state until communication is restored.
NOTE
In the event power to a Transceiver is shut off and turned back on (power cycled) the Transceiver will broadcast
continuously based on its Power-on Transmit schedule (default 8 hours). Power cycling the Transceiver can be used to
set/reset system devices. It's not recommended to power-cycle a Transceiver when in an error state, as indicated when its
front panel Error LED indicator is illuminated.
9