background image

 
 

USER MANUAL 

• 

Read this instruction before the charger is taken into use 

• 

Keep this manual within easy reach for the user of this battery charger 

• 

During charging, the batteries must be placed in a well-ventilated area 

• 

Hydrogen gas will be produced when charging lead-acid batteries and hydrogen gas is explosive 

• 

Open flames and sparks should be kept away from batteries they may produce explosions 

• 

After charging, disconnect the battery charger from the supply mains, then remove the chassis 
connection and then the battery connection 

 

General 

Primepower Workshop Charger was developed for both mobile and stationary use for charging all types of lead acid 
batteries. The charger offers three important types of operation for daily use in workshops and when making service 
calls:  

 

Fully automatic charging of 12V lead acid batteries (Wet cell, GEL, AGM) 

 

Fully automatic charging of 24V lead acid batteries (Wet cell, GEL, AGM)  

 

Power supply function for supplying batteries that have been removed from the vehicle 

 

Installation 

Primepower Workshop Charger is intended as a portable charger for use in workshops and on service calls. However, 
depending on the application and field of use, it may also be practical to mount the charger on the wall in order to 
set up a stationary charging station. For this purpose, the device has feet with appropriate openings for mounting 
bolts. A 5 m battery charging cable can be delivered as an accessory (or as a special option when purchasing a new 
charger), which can easily be exchanged with the standard charging cable that may have been part of the original 
delivery package. 
 

Function 

Insert the power cable plug into a schuko socket that is part of your indoor power circuit to switch the charger on. 
After connection to the mains, one of the five operating LEDs will start to blink, signaling the current status of 
operation. Press the Mode key to switch from one type of operation and battery to another: press and hold the 
Mode key until the LED next to the desired position lights up. Then release the Mode 
key. After a few seconds, the charger will start in the program that has been selected. 

 
If the voltage of the connected battery does not match the selection made, the orange 
LED and the red error LED lights will blink alternately to indicate an error.  
To set the correct voltage, press the Mode key and hold it until the LED next to the 
desired 12V/24V type of battery, i.e. Standard or Gel/AGM lights up. Then release the 
Mode key. After just a few seconds, the charger will start the program that has been 
selected and charge the connected battery until it is fully charged. The program runs 
fully automatically. As soon as the battery is fully charged, the LED display will switch 
from orange to green and the charging voltage will be reduced to maintenance 
charging. The battery can now be disconnected or remain connected to the charger 
until it is required. During this time, the charger ensures that the battery remains fully 
charged, irrespective of how long it stays connected to the charger. 

 

 

Содержание Workshop charger

Страница 1: ...WORKSHOP CHARGER 12 70 24 60 12 100...

Страница 2: ...ER OCH KAPACITET 6 FELS KNING 7 UNDERH LL OCH SERVICE 8 MONTERING 9 GARANTI 10 INKLUDERAT I PAKETET 10 MANUAL ENGLISH 11 CRITICAL INFORMATION 11 USER MANUAL 11 General 12 Installation 12 Function 12 C...

Страница 3: ...part i n gon form utan skriftligt medgivande fr n Primepower Varning Underl tenhet att f lja dessa s kerhetsinstruktioner kan resultera i personskada produktskada eller nedsatt funktion av laddaren Va...

Страница 4: ...ingsanordning En 5 m batteri laddningskabel kan levereras som tillbeh r eller som ett specialalternativ n r man k per en ny laddare denna kan l tt bytas ut Funktion Anslut n tsladden till ett jordat u...

Страница 5: ...a laddningsstr mmenanv nds f r att laddabatteriet beroende p sitt laddningstillst ndstatus i syfte att lagra s mycket energi s snabbt somm jligt i batteriet N r huvudladdningssp nninghar n tts 14 4 28...

Страница 6: ...Workshop Charger r avsedd f r laddning 12V 24V ppen och ventilreglerade batterier i olika storlekar Du kan enkelt v lja laddningskurvor p knappen Mode Laddningskurva GEL AGM batterier Laddningskurva S...

Страница 7: ...V batterier Back str m fr n anslutet batteri 2 mA N tkabel Gummikabel med Neutrik kontakt 1 5m Batterikablage 12 24V 60A 2 x 10mm2 2m med kl mmor 200A standard 2 x 10mm2 5m med kl mmor 200A tillval Ba...

Страница 8: ...stegen som anges nedan Om detta inte avhj lper felet kontakta din lokala terf rs ljare eller Primepower Ha serienummer och ink psdatum till hands och vara redo att beskriva felet s detaljerat som m jl...

Страница 9: ...0063 2 Charging cable 2x 10 mm2 5 m with terminal clamps 200 A 12 24V 70 60A 0360064 3 Powercord NEUTRIK 230VAC 1 5M Alla Workshop chargers 2810029 4 Powercord NEUTRIK 230VAC 5M Alla Workshop chargers...

Страница 10: ...rna av damm och fukt Se till att fl kten fritt kan suga in kylluft Placera inte laddaren direkt bredvid eller ovanf r br nnbart material Montera laddaren p en j mn horisontell eller vertikal yta De fy...

Страница 11: ...rantin kontakta din terf rs ljare eller Primepower V nlig ha f ljande information tillg nglig Kvitto Modellnummer Produktens serienummer En kort beskrivning av problemet INKLUDERAT I PAKETET VARNING A...

Страница 12: ...rm without the express written consent of Primepower Warning Failure to follow these safety instructions could result in personal injury property damage or impair the function of the charger Danger Hi...

Страница 13: ...as an accessory or as a special option when purchasing a new charger which can easily be exchanged with the standard charging cable that may have been part of the original delivery package Function In...

Страница 14: ...t is usedto charge the battery dependingonitschargedstatus so as to store asmuchenergy as quickly as possible inthe battery If a battery that has beentotally dischargedis attachedto the charger the ch...

Страница 15: ...shop Charger is designed for charging 12V 24V open and valve regulated batteries of different sizes You can easily choose charging curves on the Mode button Charging curve GEL AGM batteries Charging c...

Страница 16: ...rent from the battery 2 mA Recommended mains fuses C10 Mains cables Rubber cable with Neutrik coupler Schuko plug 1 5m Battery cables 12V 100A 2 x 25mm2 2m with terminal clamps 200A standard 2 x 25mm2...

Страница 17: ...below If this proves to be unsuccessful please contact your local dealer or PRIMEPOWER Have the serial number and date of purchase at hand and be ready to describe the error in as much detail as poss...

Страница 18: ...m with terminal clamps 200 A 12 24V 70 60A 0360063 2 Charging cable 2x 10 mm2 5 m with terminal clamps 200 A 12 24V 70 60A 0360064 3 Powercord NEUTRIK 230VAC 1 5M All Workshop chargers 2810029 4 Powe...

Страница 19: ...st be protected against the effects of dust and moisture Ensure that the fan can freely suck in cooling air Do not install the charger directly next to or above flammable materials Mount the charger o...

Страница 20: ...tage of warranty please contact your retailer Please have following information available Receipt Model number Product serial number A brief description of the problem INCLUDED IN THE PACKAGE WARNING...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...P0990255_rev2...

Отзывы: