WIRING

 

(Refer to Figure 6)

IMPORTANT:

 The power to your PRIME Air ventilation fan must disconnect before installation

 begins. Be certain all wiring complies with local codes and that the fan unit is properly ground.

1.  Run power leads from the wall switch, sensor switch or time switch to the unit.

2.     Using the approved wire connectors, connect supply wires to fan wires: black (or brown)
        to black (or brown) and white (or blue) to white (or blue).  Connected ground wire 
        (green or bare) to the ground connection in the fan’s junction box.

DUCTING

 

(Refer to Figure 7) 

1. Run 4” round duct from the air discharge opening to the outside of the 
    building.

2. Smooth sheet metal duct is recommended.

Properly insulate the area around the fan to minimize building heat loss and 
gain. Loose fill or batt insulation can be placed over the fan housing in the
attic.            

SWITCH BOX

BLACK (BROWN)

BLACK (BROWN)

WHITE (BLUE)  AC POWER

WHITE (BLUE)

GROUNDING

GROUNDING

FAN HOUSING

FIGURE 6

Dryer-hood type vent with

backdraft flap(s)

Caulk termination to duct.

2-3 ft straight run before elbow.

In attic installation,

caulk box to drywall.

Short piece of flexible duct

helps alignment and absorbs

sound. Clamps plus tape at

all flex joints.

Foil tape tightly covers all metal

duct joints (glue PVC joints).

Insulation

FIGURE 7

MAINTENANCE

 (Refer to Figure 8)

WARNING:

 Disconnect the power source before servicing.

NOTE: Never use petrol, benzene, thinner or any other chemicals for cleaning the ventilating fan.  Do not allow water get into motor.  Do 
not immerse plastic parts in hot water over 60 C.

Routine maintenance must be done every year.

1. 

Remove the louver from the fan.

2. 

Wash and clean the louver.

3. 

Using a soft cloth and dampened with mild detergent to remove any dirt or duct build-up form the unit and wipe to dry.

4. 

After cleaning, replace the louver and confirm that fan has been reassembled correctly.

 

SPECIFICATIONS

GLOVES

GRILLE

SLOT

MOUNTING

SPRING

GRILLE

VANCUUM CLEANER

Model No.

PME50
PME70
PME90

PME110
PME130

Noise

(Sones)

<0.3
<0.3

0.8
1.1
1.5

Weight

kg (lbs)

3.5

4

4.25

4.5
4.5

Air

Direction

<0.3
<0.3

0.8
1.1
1.5

Air Deliver

(CFM)

55.6
71.3
93.2

117.7
134.6

Duct

Diameter (inch)

4
4
4

4

4

Volts

120
120
120
120
120

Hz

60
60
60
60
60

Speed

(RPM)

0.23
0.22
0.24
0.29
0.34

Power

Consumption (W)

24.9
24.5
28.4
35.1
40.8

*  Static pressure at 0.1 inches of water. 
Specifications are based on HVI standard.

*  Product specifications subject to change without notice

FIGURE 8