WIRING
(Refer to Figure 6)
IMPORTANT:
The power to your PRIME Air ventilation fan must disconnect before installation
begins. Be certain all wiring complies with local codes and that the fan unit is properly ground.
1. Run power leads from the wall switch, sensor switch or time switch to the unit.
2. Using the approved wire connectors, connect supply wires to fan wires: black (or brown)
to black (or brown) and white (or blue) to white (or blue). Connected ground wire
(green or bare) to the ground connection in the fan’s junction box.
DUCTING
(Refer to Figure 7)
1. Run 4” round duct from the air discharge opening to the outside of the
building.
2. Smooth sheet metal duct is recommended.
Properly insulate the area around the fan to minimize building heat loss and
gain. Loose fill or batt insulation can be placed over the fan housing in the
attic.
SWITCH BOX
BLACK (BROWN)
BLACK (BROWN)
WHITE (BLUE) AC POWER
WHITE (BLUE)
GROUNDING
GROUNDING
FAN HOUSING
FIGURE 6
Dryer-hood type vent with
backdraft flap(s)
Caulk termination to duct.
2-3 ft straight run before elbow.
In attic installation,
caulk box to drywall.
Short piece of flexible duct
helps alignment and absorbs
sound. Clamps plus tape at
all flex joints.
Foil tape tightly covers all metal
duct joints (glue PVC joints).
Insulation
FIGURE 7
MAINTENANCE
(Refer to Figure 8)
WARNING:
Disconnect the power source before servicing.
NOTE: Never use petrol, benzene, thinner or any other chemicals for cleaning the ventilating fan. Do not allow water get into motor. Do
not immerse plastic parts in hot water over 60 C.
Routine maintenance must be done every year.
1.
Remove the louver from the fan.
2.
Wash and clean the louver.
3.
Using a soft cloth and dampened with mild detergent to remove any dirt or duct build-up form the unit and wipe to dry.
4.
After cleaning, replace the louver and confirm that fan has been reassembled correctly.
SPECIFICATIONS
GLOVES
GRILLE
SLOT
MOUNTING
SPRING
GRILLE
VANCUUM CLEANER
Model No.
PME50
PME70
PME90
PME110
PME130
Noise
(Sones)
<0.3
<0.3
0.8
1.1
1.5
Weight
kg (lbs)
3.5
4
4.25
4.5
4.5
Air
Direction
<0.3
<0.3
0.8
1.1
1.5
Air Deliver
(CFM)
55.6
71.3
93.2
117.7
134.6
Duct
Diameter (inch)
4
4
4
4
4
Volts
120
120
120
120
120
Hz
60
60
60
60
60
Speed
(RPM)
0.23
0.22
0.24
0.29
0.34
Power
Consumption (W)
24.9
24.5
28.4
35.1
40.8
* Static pressure at 0.1 inches of water.
Specifications are based on HVI standard.
* Product specifications subject to change without notice
FIGURE 8