INSTALLATION MANUAL
                 FOR VENTILATING FAN 

Models : PME 50,   PME70,   PME90,   PME110, PME130
 

PME50L, PME70L, PME90L, PME110L, PME130L

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURES WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.  THIS 
PRODUCT MUST BE INSTALLED BY A QUALIFIED TECHNICIAN 
Please read these instructions before attempting to install, operate or service the ventilation fan, Failure to comply with instruction could be 
result in personal injury and / or property damage. Please save these instructions for further reference.

INSTALLER LEAVE THIS MANUAL WITH THE HOMEOWNER

IMPORTANT SAFELY INSTRUCTIONS

WARNING:

  TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this fan in the manner intended by the manufacturer.  If you have questions, contact the manufacturer or distributors / dealer.

2.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, 

including fire rated construction.

3.  Before servicing or cleaning this fan, switch power off at service panel, and lock the service disconnecting means to prevent power 

from being switching on accidentally.

4.  Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning- equipment to 

prevent back-drafting.  Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the 
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers 
ASHRAE), and the local code authorities.

5.  When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utility.

6.  Ducted fans must always be vented to the outdoors.

7.  Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the risk of fire or electric shock, 

do not use this unit with any solid- state control device.

8.  Never place a switch where it can be reached from a tub or shower.

9.  Not t No.o be installed in a ceiling thermally insulated to a value greater than R40.

10.  These units are cULus listed for use over a tub and shower when connected to a GFCI (Ground Fault Circuit Interrupter) – protected 

branch circuit.

11.  This unit must be grounded

CAUTION:

 

Installation work and electrical wiring must be done by qualified persons in accordance with all applicable codes and standard, including 

fire-rated construction.

1.  Fan is for general ventilating use only.  Do not use to exhaust hazardous or explosive material 
 and 

vapors.

2.  Not for use in a cooking area ( Fig. 1)

3.  This fan is designed fore installation in ceiling up to a 7/12 pitch. Duct connector must point up.
 

DO NOT MOUNT THIS FAN IN A WALL.

DO NOT INSTALL ABOVE OR

INSIDE THIS AREA

COOKING

EQUIPMENT

FLOOR

FIGURE 1